![Rohde & Schwarz EX-IQ-BOX Скачать руководство пользователя страница 125](http://html1.mh-extra.com/html/rohde-and-schwarz/ex-iq-box/ex-iq-box_user-manual_1477982125.webp)
Protocol Settings
R&S
®
EX-IQ-BOX
110
User Manual 1409.5570.32 ─ 05
"LSB"
The LSB (Last Significant Bit) is mapped firmly to the same data line
and the data line of the MSB varies in dependency of the word size.
Example:
●
Fig. 7-19: User defined > Word alignment LSB: I/Q parallel transmission, 5 bit,
bit order MSB
word size
= 5
word alignment = LSB
bit order
= MSB
●
Fig. 7-20: User defined > Word alignment LSB: I/Q parallel transmission, 9 bit,
bit order LSB
word size
= 9
word alignment = LSB
bit order
= LSB
Remote command:
Bit Order
Sets the order of the data bits. In "Parallel mode", either the LSB or the MSB is transmitted
on the first used data line. In "Serial mode" either the LSB or the MSB is transmitted as
first bit.
User Defined
Содержание EX-IQ-BOX
Страница 147: ...Protocol Settings R S EX IQ BOX 132 User Manual 1409 5570 32 05 CPRI...
Страница 391: ......