GBAS:LEV?
<Slot>
LA?
<Slot>
Queries the arithmetic average of the burst power level measured over the period of
the synchronization and ambiguity resolution field of the burst.
If no burst was detected, the arithmetic average of the noise power is returned.
Parameters:
<Slot>
0 | 1 | 2 | 3 | 4 | 5 | 6 | 7
Selects the slot for which results are queried.
Return values:
<Freq>
Signal level
Default unit: dBm
Example:
GBAS:LEV? 2
Usage:
Query only
Manual operation:
See
"Burst Level Average (Av [dBm])"
MODE_GBAS
This command starts GBAS mode.
Return values:
<State>
READY.
Command was executed successfully.
GBAS:SCREENVIEW ?
<View>
GBAS:SCREENVIEW
<View>
This command sets or queries the displayed measurement view in "GBAS" mode.
Parameters:
<View>
SEQUENCE | FRAME | BURST | CONSTELLATION |
MESSAGE | REC
*RST:
SEQUENCE
<State>
READY.
The command was executed successfully.
GBAS:SEQN_SLOT?
<Slot>
GBAS:SEQN_SLOT
<Slot>
Gets or sets the slot to be displayed in the power vs. time diagram and at the top of the
results table in "GBAS" mode.