COM_DEFAULT_FREQSTEP?
<StepSize>
COM_DEFAULT_FREQSTEP
<StepSize>
Gets or sets the default RF frequency step size in "COM" mode.
Parameters:
<StepSize>
8.33_KHZ | 12.5_KHZ | 25_KHZ | 50_KHZ
*RST:
50_KHZ
Return values:
<State>
READY.
The command was executed successfully.
COM_DEMOD_BW_1F?
COM_DEMOD_BW_1F
<Bandwidth>
Gets or sets the 1F demodulator bandwidth in "COM" mode.
Parameters:
<Bandwidth>
1KHZ | 3KHZ | 6KHZ | 10KHZ
Return values:
<State>
READY.
The command was executed successfully.
Manual operation:
See
COM_DEMOD_BW_2F?
COM_DEMOD_BW_2F
<Bandwidth>
Gets or sets the 2F demodulator bandwidth in "COM" mode.
Parameters:
<Bandwidth>
1KHZ | 3KHZ | 6KHZ | 10KHZ
Return values:
<State>
READY.
The command was executed successfully.
Manual operation:
See
COM_TONEFREQ_1K01K2?
<Frequency>
COM_TONEFREQ_1K01K2
<Frequency>
Gets or sets the tone frequency to measure AM and distortion values in "COM" mode.
Parameters:
<Frequency>
Tone frequency
Default unit: kHz
Return values:
<State>
READY.
The command was executed successfully.