Remote Commands
R&S
®
EVSG1000
307
User Manual 1178.6227.02 ─ 06
POSITIVE
Triggers when the signal rises to the trigger level
NEGATIVE
Triggers when the signal falls down to the trigger level
Return values:
<State>
READY.
The command was executed successfully.
MB_TRIG_SOURCE?
<TrigSource>
MB_TRIG_SOURCE
<TrigSource>
Gets or sets the trigger source in "ILS MB" mode.
Parameters:
<TrigSource>
OFF | TIME | EXT
OFF
Free run mode, no trigger used
TIME
time trigger
EXT
external trigger
Return values:
<State>
READY.
The command was executed successfully.
VIEW_MB
<View type>
This command selects a view type for the MB mode.
Parameters:
<View type>
MAIN | DIST | LOG
Available views for the MB mode.
Return values:
<State>
READY.
The command was executed successfully.
10.3.2
Retrieving ILS MB Results
The following commands are required to retrieve results from ILS MB measurements.
Useful commands for retrieving results described elsewhere:
●
●
ILS Marker Beacon (MB) Mode