Remote Commands
R&S
®
EVSG1000
245
User Manual 1178.6227.02 ─ 06
MEASTIME?
MEASTIME
<Time>
This command gets or sets the measurement time for "ILS LOC","ILS GP", "ILS MB",
"VOR" and "COM" mode.
Parameters:
<Time>
Measurement time
Default unit: ms
Return values:
<State>
READY.
The command was executed successfully.
RF?
RF
This command sets RF frequency. All values are interpreted with one digit behind the
decimal point, for example, RF 108700.5 in numeric measurement modes.
Parameters:
<freq>
RF frequency
Default unit: kHz
Return values:
<State>
READY.
The command was executed successfully.
Manual operation:
See
See
See
See
RFCH
<Channel>
This command sets the receiver frequency channel on the active receiver board
according to the ICAO frequency list, or returns the currently defined channel.
Parameters:
<Channel>
The specified ICAO-channel for the measurement. See
ter A, "ILS Channel Frequency List"
Return values:
<State>
READY.
The command was executed successfully.
Manual operation:
See
Common Instrument and Measurement Setup