GBAS/SCAT-I Mode (Options R&S
EVSG-K4/-K5)
R&S
®
EVSG1000
170
User Manual 1178.6227.02 ─ 06
6
GBAS/SCAT-I Mode (Options R&S
EVSG-
K4/-K5)
Access
: [Mode] > "GBAS"
Access VNC
: [m] > Down arrow key
The R&S
EVSG-K4/-K5 options are firmware applications that add functionality to per-
form GBAS and SCAT-I analysis on the R&S
EVSG1000.
The R&S
EVSG-K4 option enables you to receive and analyze the very high frequency
(VHF) data broadcast (VDB) signal-in-space transmitted from a ground-based aug-
mentation system (GBAS) ground subsystem to the airborne subsystem. This imple-
mentation is in line with the specification ICAO AN10 Vol1 [3] and RTCA DO-246 [1]
(see
Similarly, using option R&S
EVSG-K5, data from special category I (SCAT-I) systems
can be received and analyzed. The main difference is the content of the message data.
This implementation is in line with the specification ICAO AN10 Vol1 [3] and RTCA
DO-217 [2] (see
The R&S
EVSG-K4/-K5 applications feature:
●
Receiving GBAS signal data from a GBAS ground station in a frequency range
between 108.025
MHz and 117.950
MHz with a channel spacing of 25
kHz
●
Receiving SCAT-I signal data from a SCAT-I ground station in a frequency range
between 108.025
MHz and 117.950
MHz with a channel spacing of 25
kHz
●
Analyzing the RF characteristics, signal strength and frequency accuracy of the
GBAS/SCAT-I signal
●
Demodulating, decoding and displaying GBAS/SCAT-I signal data
●
Analyzing up to 8 time slots or individual time slot details in the GBAS/SCAT-I sig-
nal data
●
Analyzing individual Final Approach Segment (FAS) data blocks
●
Logging and storing up to 9999 lists of received GBAS/SCAT-I signal data
We strongly recommend that you provide a PPS signal for reference. Without PPS
synchronization, signal timing and slot positions may not be correct.
For details, see
Chapter 6.1.4, "Time Slot Synchronization via PPS"
Basics on GBAS and SCAT-I Analysis
.................................................................171
GBAS / SCAT-I Measurement Information
............................................................174
GBAS / SCAT-I Measurement Views and Results
................................................ 176
GBAS/ SCAT-I Measurement Configuration
......................................................... 189