Spectrum Measurements
R&S
®
ESRP
245
User Manual 1175.7445.02 ─ 08
Label
Description
Range Up
Frequency range stop for range the peak value belongs to
RBW
RBW of the range
Frequency
Frequency
Power Abs
Absolute power level
Power Rel
Power level relative to the TX channel power
Δ
Limit
Deviation of the power level from the defined limit
In which detail the data is displayed in the result table can be defined in the
menu. By default, one peak per range is displayed. However, you can change the
settings to display only peaks that exceed a threshold ("Margin").
In addition to listing the peaks in the list evaluation, detected peaks can be indicated by
blue squares in the diagram ("Show Peaks").
Furthermore, you can save the evaluation list to a file ("Save Evaluation List").
Retrieving Results via Remote Control
The measurement results of the spectrum emission mask test can be retrieved using
the
command from a remote computer.
The power result for the reference range can be queried using
CALC:MARK:FUNC:POW:RES? CPOW
, the peak power for the reference range using
CALC:MARK:FUNC:POW:RES? PPOW
.
For details see
CALCulate<n>:MARKer<m>:FUNCtion:POWer:RESult?
Ranges and Range Settings
In the Spectrum Emission Mask measurements, a range defines a segment for which
you can define the following parameters separately:
●
Start and stop frequency
Measurements