CDMA2000 Measurements
R&S
®
CMW-KM8xx/-KS8xx
774
User Manual 1173.9511.02 ─ 12
●
Use general commands of the type
...:CDMA:MEAS...
to define the signal rout-
ing and perform RF and analyzer settings.
●
Trigger setting commands are the same as by the multi evaluation measurement,
see
Configuring the Trigger System
●
After a
*RST
, the measurement is switched off. Use
READ:CDMA:MEAS:OLTR...?
to initiate a single-shot measurement and retrieve
the results. You can also start the measurement using
INIT:CDMA:MEAS:OLTR
and retrieve the results using
FETCh:CDMA:MEAS:OLTR...?
/
FETCh:CDMA:MEAS:RPINterval...?
.
// *************************************************************************
// Define measurement timeout, no. of sequences for
// single-shot measurement, power step 30 dB, direction up,
// reference power interval 20 ms, guard interval 50 ms,
// measure on exception and initial lower OLTR limit.
// *************************************************************************
CONFigure:CDMA:MEAS:OLTR:TOUT 5
CONFigure:CDMA:MEAS:OLTR:SEQuence 5
CONFigure:CDMA:MEAS:OLTR:PSTep 30
CONFigure:CDMA:MEAS:OLTR:PSTep:DIRection UP
CONFigure:CDMA:MEAS:OLTR:RPINterval 12
CONFigure:CDMA:MEAS:OLTR:RPINterval:TIME?
CONFigure:CDMA:MEAS:OLTR:GINTerval 30
CONFigure:CDMA:MEAS:OLTR:GINTerval:TIME?
CONFigure:CDMA:MEAS:OLTR:MOEXception ON
CONFigure:CDMA:MEAS:OLTR:LIMit:ILOWer -2
5.4.1.8
OLTR: Single-Shot Measurement
// *************************************************************************
// Start single-shot measurement for the open loop time response for
// BS power up (resulting in DUT's power down), and return the result
// trace and the limit violation evaluation for the second sequence
// (of the five configured), and also the trace of the reference
// power interval. Query the measurement state (should be "RDY").
// Query measurement state and substates (should be "RUN,ADJ,ACT").
// *************************************************************************
INITiate:CDMA:MEAS:OLTR
FETCh:CDMA:MEAS:OLTR:SEQuence2:TRACe:DOWN?
FETCh:CDMA:MEAS:OLTR:SEQuence2:TRACe:DOWN:STATe?
FETCh:CDMA:MEAS:RPINterval:SEQuence2:TRACe:DOWN?
FETCh:CDMA:MEAS:OLTR:STATe?
FETCh:CDMA:MEAS:OLTR:STATe:ALL?
Programming
深圳德标仪器
135-1095-0799