
1xEV-DO Measurements
R&S
®
CMW-KM8xx/-KS8xx
335
User Manual 1173.9511.02 ─ 12
Example:
See
Firmware/Software:
V1.0.3.3
Manual operation:
See
CONFigure:EVDO:MEAS<i>:MEValuation:LIMit:EVM:PEAK
<EVMPeak>
Defines an upper limit for the peak values of the error vector magnitude (EVM).
Parameters:
<EVMPeak>
Range:
0 % to 100 %
*RST:
33.4 %
Default unit: %
Additional parameters: OFF | ON (disables the limit check | ena-
bles the limit check using the previous/default limit values)
Example:
See
Firmware/Software:
V1.0.3.3
Manual operation:
See
CONFigure:EVDO:MEAS<i>:MEValuation:LIMit:MERR:RMS
<MErrRMS>
Defines an upper limit for the RMS values of the magnitude error.
Parameters:
<MErrRMS>
Range:
0 % to 100 %
*RST:
23.6 %
Default unit: %
Additional parameters: OFF | ON (disables the limit check | ena-
bles the limit check using the previous/default limit values)
Example:
See
Firmware/Software:
V1.0.3.3
Manual operation:
See
CONFigure:EVDO:MEAS<i>:MEValuation:LIMit:MERR:PEAK
<MErrPeak>
Defines an upper limit for the peak values of the magnitude error.
Parameters:
<MErrPeak>
Range:
0 % to 100 %
*RST:
33.4 %
Default unit: %
Additional parameters: OFF | ON (disables the limit check | ena-
bles the limit check using the previous/default limit values)
Example:
See
Firmware/Software:
V1.0.3.3
Command Reference
深圳德标仪器
135-1095-0799