1xEV-DO Measurements
R&S
®
CMW-KM8xx/-KS8xx
273
User Manual 1173.9511.02 ─ 12
Setting carrier 0's frequency is equivalent to setting the "Frequency" in the RF Settings
(see
).
In the Standalone (SA) scenario, these parameters are controlled by the measurement.
In the Combined Signal Path (CSP) scenario, they are controlled by the signaling appli-
cation.
Remote command:
CONFigure:EVDO:MEAS<i>:MEValuation:CARRier:SETTing
(SA)
CONFigure:EVDO:MEAS<i>:MEValuation:CARRier:FOFFset
(SA)
CONFigure:EVDO:MEAS<i>:MEValuation:CARRier:FREQuency
(SA)
CONFigure:EVDO:SIGN<i>:CARRier:SETTing
(CSP)
CONFigure:EVDO:SIGN<i>:CARRier:CHANnel
(CSP)
CONFigure:EVDO:SIGN<i>:CARRier:RLFRequency?
(CSP)
WB Filter
Selects the bandwidth of the wideband filter used to measure the "AT Power (Wide-
band)": 8 MHz or 16 MHz. For multi-carrier configurations the filter bandwidth is fixed to
16 MHz.
Remote command:
CONFigure:EVDO:MEAS<i>:MEValuation:CARRier:WBFilter
3.3.6 Multi Evaluation: Code Channel Filter
The channel setup determines the code channel filter and the modulation type of the
data channel.
Fig. 3-24: Multi evaluation configuration: code channel filter
Half Slot
Selects which half-slot(s) of the code channel is/are evaluated. This setting is not avail-
able for physical layer subtype 0/1. Note that the DSC channel and the ACK channel
are transmitted time-multiplexed on the same Walsh channel: the ACK is transmitted
on the first half-slot and the DSC on the second half-slot.
Remote command:
CONFigure:EVDO:MEAS<i>:MEValuation:HSLot
GUI Reference
深圳德标仪器
135-1095-0799