Remote Control Commands
R&S
®
AREG100A
250
User Manual 1178.7417.02 ─ 04
[:SOURce<hw>]:AREGenerator:UNITs:RCS
<AregUnitRcs>
Defines the unit of the radar cross section.
Parameters:
<AregUnitRcs>
DBSM | SM
DBSM
Radar cross section in dB relative to one square meter.
SM
Radar cross section in m
2
(square meters).
*RST:
DBSM
Example:
:SOURce:AREGenerator:UNITs:RCS SM
Manual operation:
See
[:SOURce<hw>]:AREGenerator:UNITs:SPEed
<AregUnitSpeed>
Defines the speed unit.
Parameters:
<AregUnitSpeed>
KMH | MPH | MPS
KMH
Kilometer per hour
MPH
Miles per Hour
MPS
Meter per Seconds
*RST:
KMH
Example:
:SOURce:AREGenerator:UNITs:SPEed KMH
Manual operation:
See
9.14
SENSe, READ, INITiate and SLISt Subsystems
These subsystems contain the commands for configuring the power measurements
with R&S NRP power sensor connected to the R&S
AREG100A.
The local state is set with the
INIT
command. Switching off the local state enhances
the measurement performance. Measurements results can be retrieved in local state
on or off.
Sensor parameters are set with the
SENSe
commands.
To start the measurement and retrieve the result, use the
command.
SENSe, READ, INITiate and SLISt Subsystems