Remote Control Commands
R&S
®
NGP800
163
User Manual 5601.5610.02 ─ 04
MAX | MAXimum
Maximum duration of the data logging captured at 3.49*10^5 s.
Default unit: s
Parameters for setting and query:
<span>
MIN | MINimum | MAX | MAXimum
Returns the duration of the data logging.
Example:
LOG:DUR MAX
LOG:DUR? MAX
-> 349000
LOG:FNAMe
<Set new value>
Sets or queries the filename and storage location for the data logging.
Setting parameters:
<Set new value>
Example:
LOG 0
LOG:FNAM?
-> ""
LOG 1
LOG:FNAM?
-> "/int/logging/log-20190318T1141853.407.csv"
Enables the data logging and queries the data log filename.
LOG:INTerval
<Set new value>[, <Return min or max>]
LOG:INTerval?
[<Return min or max>]
Sets or queries the data logging measurement interval. The measurement interval
describes the time between the recorded measurements.
Setting parameters:
<interval>
<numeric value> | MIN | MINimum | MAX | MAXimum
<numeric value>
Measurement interval in the range of 0.1 s to 600 s.
MIN | MINimum
Minimum measurement interval is set at 0.1 s.
MAX | MAXimum
Maximum measurement interval is set at 600 s.
Default unit: s
Parameters for setting and query:
<Return min or max> MIN | MINimum | MAX | MAXimum
Returns the measurement interval.
Example:
LOG:INT 10
LOG:INT?
-> 10
Data and File Management Commands
www.allice.de
Allice Messtechnik GmbH