Remote Control Commands
R&S
®
NRX
233
User Manual 1178.5566.02 ─ 08
CALCulate<Measurement>:TRACe:Y[:SCALe]:SPAN:DBUV
.............................................. 240
CALCulate<Measurement>:TRACe:Y[:SCALe]:SPAN:DPCT
.............................................. 240
CALCulate<Measurement>:TRACe:Y[:SCALe]:SPAN:ONE
................................................ 241
CALCulate<Measurement>:TRACe:Y[:SCALe]:SPAN:WATT
.............................................. 241
CALCulate<Measurement>:TRACe:Y[:SCALe]:TOP:DB
.....................................................241
CALCulate<Measurement>:TRACe:Y[:SCALe]:TOP:DBM
..................................................242
CALCulate<Measurement>:TRACe:Y[:SCALe]:TOP:DBUV
................................................ 242
CALCulate<Measurement>:TRACe:Y[:SCALe]:TOP:DPCT
................................................ 242
CALCulate<Measurement>:TRACe:Y[:SCALe]:TOP:ONE
.................................................. 243
CALCulate<Measurement>:TRACe:Y[:SCALe]:TOP:WATT
................................................ 243
DISPlay[:WINDow<Window>]:ANALog:AUTO
................................................................... 243
DISPlay[:WINDow<Window>]:METer:AUTO
......................................................................243
DISPlay[:WINDow<Window>]:ANALog:LOWer
..................................................................244
DISPlay[:WINDow<Window>]:METer:LOWer
.................................................................... 244
DISPlay[:WINDow<Window>]:ANALog:UPPer
.................................................................. 244
DISPlay[:WINDow<Window>]:METer:UPPer
..................................................................... 244
[SENSe<Sensor>:]TRACe:OFFSet:TIME
......................................................................... 244
......................................................................................245
CALCulate<Measurement>:METer<DirectionalChannel>:LOWer[:DATA]:CCDF
<value>
Sets the lower limit for the CCDF bargraph display.
Suffix:
<Measurement>
.
1 to 8
Measurement
<DirectionalChannel> 1 to 2
1 = primary sensor, 2 = secondary sensor or 1 = forward, 2 =
reflection (reverse)
Parameters:
<value>
Range:
0.0 to 100.0
*RST:
0.0
Default unit: pct
Manual operation:
See
"Forward Scale Lower Limit, Reflection Scale Lower Limit"
CALCulate<Measurement>:METer<DirectionalChannel>:LOWer[:DATA]:RATio:
RCOefficient
<value>
Sets the lower limit for the reflection coefficient bargraph display.
Suffix:
<Measurement>
.
1 to 8
Measurement
<DirectionalChannel> 1 to 2
1 = primary sensor, 2 = secondary sensor or 1 = forward, 2 =
reflection (reverse)
Measurement Settings and Results
www.allice.de
Allice Messtechnik GmbH