Remote control commands
R&S
®
RTM3000
642
User Manual 1335.9090.02 ─ 09
Parameters:
<IdentifierType>
B11 | B29 | ANY
ANY: use if the identifier length is not relevant. Not available for
trigger type
ID
.
*RST:
B11
TRIGger:A:CAN:ICONdition
<IdentifierCondition>
Sets the comparison condition: If the pattern contains at least one X (don't care), you
can trigger on values equal or not equal to the specified value. If the pattern contains
only 0 and 1, you can also trigger on a range greater than or lower than the specified
value.
The command is relevant, if
ID
or
IDDT
.
Parameters:
<IdentifierCondition> EQUual | NEQual | GTHan | LTHan
*RST:
EQ
TRIGger:A:CAN:IDENtifier
<Identifier>
Defines the identifier pattern. The pattern length is defined with
.
is set to
ID
or
IDDT
.
Parameters:
<Identifier>
String containing binary pattern with 11 bit or 29 bit. Characters
0, 1, and X are allowed.
TRIGger:A:CAN:DCONdition
<DataCondition>
Sets the comparison condition for data: If the pattern contains at least one X (don't
care), you can trigger on values equal or not equal to the specified value. If the pattern
contains only 0 and 1, you can also trigger on a range greater than or lower than the
specified value.
is set to
IDDT
.
Parameters:
<DataCondition>
EQUal | NEQual | GTHan | LTHan
*RST:
EQ
TRIGger:A:CAN:DLC
<DataLength>
Defines the length of the data pattern - the number of bytes in the pattern.
is set to
IDDT
.
Serial bus analysis