Roger Access Control System
RKD32 Installation Manual
Product version: 1.0
App version: 1.3.2
Document version: Rev. C
Страница 1: ...Roger Access Control System RKD32 Installation Manual Product version 1 0 App version 1 3 2 Document version Rev C...
Страница 2: ...articular keys Typically users are identified at the panel with Mifare proximity cards or PINs When key is collected then both door lock and fob lock are released and frame around the key is highlight...
Страница 3: ...e RKD32 can be supplied from powerbank min 2A rated output connected to USB cable which is connected to RKD board fig 4 Cabinet RKD32 cabinet is made of stainless metal sheet which is powder painted i...
Страница 4: ...ntly increases security in the system More information on MIFARE cards with PCN is given in section 7 and in AN024 application note which is available at www roger pl PINs The panel accepts variable l...
Страница 5: ...system In case of fire alarm detection or any other emergency situation the RKD32 can release all locks to enable key collecting by any person without authorisation Such release requires connection of...
Страница 6: ...RKD32 Installation and Configuration Manual doc 16 10 2020 6 20 Fig 5 Back cover Fig 6 Wall mounting...
Страница 7: ...ration Manual doc 16 10 2020 7 20 Fig 7 Connection of additional cabinets RKD32EXT to main cabinet RKD32 Fig 8 RKD and MCX4D boards Table 1 Screw terminals and sockets Terminal socket Description 12V...
Страница 8: ...CA APP After connection of power supply the MD70 panel will start RAACA app When started for the first time the panel will offer to create default Master user with 9999 password You must also select t...
Страница 9: ...White No unconfirmed alarms Orange Alarm s from the past is are in the memory of device Red At least one unconfirmed alarm is still on When is selected then office mode will be started after returnin...
Страница 10: ...Report Centre can be exported to pendrive connected to MASTER USB socket fig 9 exported to internal memory or sent by email according to settings in Configuration window table 2 Available formats are...
Страница 11: ...configuration Cards PINs When selected then list of cards and PINs is displayed Cards and PINs are used for identification of users at MD70 panel Adding editing and deleting is possible on the list D...
Страница 12: ...and the mode of any key position and for the user who has no access to the application settings Default value OFF Shortcut logout after get single key The parameter activates automatic logout after g...
Страница 13: ...nables SSL encryption for email sending Range ON OFF Default value OFF Address 1 Recipient email address Address 2 Recipient additional email address Table 3 Commands in menu in Configuration window A...
Страница 14: ...nu in Settings windows Show launcher Command enables to exit RKD32 app and start Android environment Default password is admin System settings Command enables configuration of Android system settings...
Страница 15: ...og in at the panel default PIN 9999 select and then Users 2 In the opened window select Add 3 In the next window name the user e g first and last name Click Cards PINs to assign previously defined fac...
Страница 16: ...etwork The IP address of the panel in LAN WAN is configured by means of Ethernet app after exiting RAACA app with the command Show launcher table 4 Prior to establishing connection with the RKD32 it i...
Страница 17: ...thod is defined for MD70 panel then its reader cannot be used for fob enrolment and for quick fob return mode Mifare cards are programmed with RogerVDM software and RUD series reader e g RUD 3 DES Car...
Страница 18: ...p to Roger technician so he could connect remotely Then accept the connection request from Roger technician on the RKD32 panel 8 TROUBLESHOOTING Table 5 Troubleshooting Issue Solution Key is inserted...
Страница 19: ...KD32EXT 535 x 675 x 183 mm Weight RKD32 28 kg RKD32EXT 27 5 kg Certificates CE Note Due to the production technology are permissible minor variations in the shade of the housing between production bat...
Страница 20: ...oints of electric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type o...