RFT1000 in RACS 5 User Manual.doc
2017-10-05
12/13
Table 6. User identification by RFT1000 when input with function [5] is used.
Recognition
mode
Card
Reader
Mode
User identification
1:N
Input with the
function
[5]
deactivated
Place finger on RFT1000 scanner.
1:N
Input with the
function
[5]
activated
Place finger on RFT1000 scanner or read proximity card.
1:1
Input with the
function
[5]
deactivated
Place your Mifare proximity card in vicinity of RFT1000 reader and
when two beeps sound is made, place your finger on RFT1000
scanner. Users with Master authorization can use their cards and
they do not have to scan their fingerprints in order to get access.
1:1
Input with the
function [92]
activated
Read proximity card.
4.6 Full memory reset
Full memory reset erases current settings, including users data base and restores factory default
settings.
Reset procedure
1.
Switch off power supply to RFT1000.
2.
Remove connections to CLK and IN2 terminals.
3.
Connect CLK terminal with IN2 terminal.
4.
Switch on power supply to RFT1000. The reader shall generate continuous acoustic signal.
5.
Disconnect CLK and IN2 terminals.
Communication parameters after reset:
IP address = 192.168.0.70
Subnet mask = 255.255.255.0
Port = 13544
Communication is encrypted with default (empty) password
4.7 Firmware update
Firmware update is performed by means of RogerVDM software. In order to update the firmware
after establishing connection with RFT1000:
1.
Select the command
Tools
in the top menu of RogerVDM software and then select
Update
Firmware.
2.
In the opened window select RFT1000 firmware file (*.frg extension) by means of the button
Select file
3.
Select the button
Update
in order to upload the firmware to RFT1000
RFT1000 keeps all its settings (including IP address) after firmware update.