Roger MCT68ME-IO Скачать руководство пользователя страница 1

MCT68ME-IO Installation Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2022-05-13 

 

1/2 

 

Roger Access Control System 

MCT68ME Installation Manual 

Firmware version: 2.1.0.306 and newer 

Document version: Rev. B 

 

This  document  contains  minimum  information  that  is  necessary  for  initial  setup 
and  installation  of  the  device.  The  detailed  description  of  configuration 
parameters  and  functionalities  is  specified  in  respective  Operating  manual 
available a

www.roger.pl

I

NTRODUCTION

 

The  reader  is  designed  for  operation  with  MC16  access  controller  (RACS  5 
system). Factory new reader is configured with default settings including ID=100 
address. MCT68ME reader is available in indoor and outdoor versions. The latter 
one is equipped with additional, protecting metal enclosure. 

D

EVICE CONFIGURATION

 

The  reader  can  be  configured  in  regard  of  various  parameters  (including 
address)  in  order  to  adapt  it  to  the  requirements  of  specific  installation.  Device 
can  be  configured  from  VISO  v2  management  software  or  RogerVDM  utility 
software. 

C

ONFIGURATION WITH 

VISO

 V

2

 PROGRAM

 

In  RACS  5  v2  system  the  reader  can  be  installed  at  site  without  previous 
configuration.  According  to  AN006  application  note,  its  address  and  other 
settings can be configured from VISO v2 management software and during such 
configuration the access to its service contacts (fig. 2) is not required. 

C

ONFIGURATION WITH 

R

OGER

VDM

 PROGRAM

 

 

Fig. 1 Connection of MCT terminal to RUD-1 interface 

Programming procedure: 

1.  Connect  the  device  to  RUD-1  interface  (fig.  1)  and  connect  the  RUD-1  to 

computer’s USB port. 

2.  Start  RogerVDM  program,  select 

MCT

  device,  firmware  version, 

RS485

 

communication channel and serial port with RUD-1 interface. 

3.  Click 

Connect,

  the  program  will  establish  connection  and  will  automatically 

display 

Configuration

 tab. 

4.  Enter  unoccupied  RS485  address  in  range  of  100-115  and  other  settings 

according to requirements of specific installation. 

5.  Click 

Send to Device

 to update the configuration of device. 

6.  Optionally  make  a  backup  by  clicking 

Send  to  File… 

and  saving  settings  to 

file on disk. 

7.  In the top menu select 

Device->Disconnect.

 

8.  Disconnect device from RUD-1 interface. 

Note: Do not read any cards nor press reader keypad when reader is configured 
with RogerVDM. 

M

EMORY RESET

 

Memory reset procedure enables configuration of RS485 address and resets all 
other settings to factory default ones.  

Memory reset procedure: 

1.  Remove all connections from A and B lines. 
2.  Place jumper on MEM contacts (fig. 2) 
3.  Restart the device (switch power supply off and on or short RST contacts for 

a moment). 

4.  When 

‘CONFIG  RESET’  is  displayed  by  reader  then  remove  jumper  from 

MEM contacts. 

5.  When 

‘ID:’  is  displayed  by  reader  then  enter  3  digits  of  RS485  address  in 

range of 100-115 with reader keypad. 

6.  When  the  third  digit  is  defined  then  the  reader  will  restart  with  the  new 

address. 

F

IRMWARE UPDATE

 

The  update  requires  connection  of  reader  to  computer  with  RUD-1  interface     
(fig.  1)  and  starting  RogerISP  software.  The  latest  firmware  file  is  available  at 

www.roger.pl

Firmware update procedure: 

1.  Connect  the  reader  to  RUD-1  interface  (fig.  1)  and  connect  the  RUD-1  to 

computer’s USB port. 

2.  Place jumper on FDM contacts (fig. 2). 
3.  Restart the reader (switch power supply off and on or short RST contacts for 

a moment). 

4.  Start RogerISP program. 
5.  Select serial port with RUD-1 interface and 

USB-RS485 Converter

 option. 

6.  Specify path to firmware file (*.hex). 
7.  Click 

Program

 and proceed according to displayed messages. 

8.  Remove jumper from FDM contacts and restart the reader. 

A

PPENDIX

 

 

Fig. 2 Service contacts 

 

Table 1. Terminals 

Screw terminal 

Description 

12V 

Supply plus 

GND 

Ground 

IN1 

IN1 input line 

IN2 

IN2input line 

IN3 

IN3 input line 

RS485 A 

RS485 bus, line A 

RS485 B 

RS485 bus, line B 

CLK 

Not used 

DTA 

Input/output line 

TMP 

Tamper contact 

TMP 

Tamper contact 

IO1 

IO1 output line 

IO2 

IO2 output line 

REL1-NC 

REL1 relay output (NC) 

REL1-COM 

REL1 relay common terminal 

REL1-NO 

REL1 relay output (NO) 

 