MCT68ME-IO Installation Manual
2022-05-13
1/2
Roger Access Control System
MCT68ME Installation Manual
Firmware version: 2.1.0.306 and newer
Document version: Rev. B
This document contains minimum information that is necessary for initial setup
and installation of the device. The detailed description of configuration
parameters and functionalities is specified in respective Operating manual
available at
I
NTRODUCTION
The reader is designed for operation with MC16 access controller (RACS 5
system). Factory new reader is configured with default settings including ID=100
address. MCT68ME reader is available in indoor and outdoor versions. The latter
one is equipped with additional, protecting metal enclosure.
D
EVICE CONFIGURATION
The reader can be configured in regard of various parameters (including
address) in order to adapt it to the requirements of specific installation. Device
can be configured from VISO v2 management software or RogerVDM utility
software.
C
ONFIGURATION WITH
VISO
V
2
PROGRAM
In RACS 5 v2 system the reader can be installed at site without previous
configuration. According to AN006 application note, its address and other
settings can be configured from VISO v2 management software and during such
configuration the access to its service contacts (fig. 2) is not required.
C
ONFIGURATION WITH
R
OGER
VDM
PROGRAM
Fig. 1 Connection of MCT terminal to RUD-1 interface
Programming procedure:
1. Connect the device to RUD-1 interface (fig. 1) and connect the RUD-1 to
computer’s USB port.
2. Start RogerVDM program, select
MCT
device, firmware version,
RS485
communication channel and serial port with RUD-1 interface.
3. Click
Connect,
the program will establish connection and will automatically
display
Configuration
tab.
4. Enter unoccupied RS485 address in range of 100-115 and other settings
according to requirements of specific installation.
5. Click
Send to Device
to update the configuration of device.
6. Optionally make a backup by clicking
Send to File…
and saving settings to
file on disk.
7. In the top menu select
Device->Disconnect.
8. Disconnect device from RUD-1 interface.
Note: Do not read any cards nor press reader keypad when reader is configured
with RogerVDM.
M
EMORY RESET
Memory reset procedure enables configuration of RS485 address and resets all
other settings to factory default ones.
Memory reset procedure:
1. Remove all connections from A and B lines.
2. Place jumper on MEM contacts (fig. 2)
3. Restart the device (switch power supply off and on or short RST contacts for
a moment).
4. When
‘CONFIG RESET’ is displayed by reader then remove jumper from
MEM contacts.
5. When
‘ID:’ is displayed by reader then enter 3 digits of RS485 address in
range of 100-115 with reader keypad.
6. When the third digit is defined then the reader will restart with the new
address.
F
IRMWARE UPDATE
The update requires connection of reader to computer with RUD-1 interface
(fig. 1) and starting RogerISP software. The latest firmware file is available at
Firmware update procedure:
1. Connect the reader to RUD-1 interface (fig. 1) and connect the RUD-1 to
computer’s USB port.
2. Place jumper on FDM contacts (fig. 2).
3. Restart the reader (switch power supply off and on or short RST contacts for
a moment).
4. Start RogerISP program.
5. Select serial port with RUD-1 interface and
USB-RS485 Converter
option.
6. Specify path to firmware file (*.hex).
7. Click
Program
and proceed according to displayed messages.
8. Remove jumper from FDM contacts and restart the reader.
A
PPENDIX
Fig. 2 Service contacts
Table 1. Terminals
Screw terminal
Description
12V
Supply plus
GND
Ground
IN1
IN1 input line
IN2
IN2input line
IN3
IN3 input line
RS485 A
RS485 bus, line A
RS485 B
RS485 bus, line B
CLK
Not used
DTA
Input/output line
TMP
Tamper contact
TMP
Tamper contact
IO1
IO1 output line
IO2
IO2 output line
REL1-NC
REL1 relay output (NC)
REL1-COM
REL1 relay common terminal
REL1-NO
REL1 relay output (NO)