Rockwell Automation Publication 1783-UM007F-EN-P - September 2016
423
Troubleshoot the Switch
Chapter 9
Access Direct Managed Mode
You can display Device Manager and manage the switch through a physical
connection between one of the switch ports and your computer or laptop. This
type of management connection is referred to as the Direct Managed mode.
This mode is typically used to connect to the switch by using Device Manager
when the IP address of the switch is unknown.
Before you can access Direct Managed mode, you must make sure of the
following:
• You must have physical access to the switch.
• Make sure that at least one switch port is enabled and is not connected
to a device.
To access the Direct Managed mode, follow these steps.
1. Press the Express Setup button until the Setup status indicator blinks
green and the status indicator of an available switch downlink port
blinks green.
The port with a flashing green status indicator is designated as the
Direct Managed mode port:
• If all downlink ports are not connected to devices or if multiple
downlink ports are connected to devices, the first available downlink
port becomes the Direct Managed mode port.
• If only one downlink port is connected to a device, that port is selected
as the Direct Managed mode port.
If there is no available switch downlink port to which to connect your
computer or laptop, disconnect a device from one of the switch
downlink ports. Press the Setup
button until the Setup and port status
indicators flash green.
2. To connect your computer to the switch port with the flashing status
indicator, use a Category 5 Ethernet cable.
3. Wait until the port status indicators on the switch and your computer or
laptop are solid green.
The solid green indicators mean a successful connection between the
two devices.
4. Start a web browser on your computer.
A password prompt followed by the Device Manager window appears.
If the Device Manager window does not appear, make sure that any pop-
up blockers or proxy settings in your browser are disabled. Also, make
sure that any wireless clients on your computer or laptop are disabled.
If the Device Manager window still does not appear, enter a URL in
your browser, such as
http://www.rockwellautomation.com
. The
browser redirects to Device Manager.
Содержание ArmorStratix 5700 series
Страница 12: ...12 Rockwell Automation Publication 1783 UM007F EN P September 2016 Table of Contents Notes...
Страница 14: ...14 Rockwell Automation Publication 1783 UM007F EN P September 2016 Preface Notes...
Страница 16: ...16 Rockwell Automation Publication 1783 UM007F EN P September 2016 Summary of Changes Notes...
Страница 156: ...156 Rockwell Automation Publication 1783 UM007F EN P September 2016 Chapter 5 Install Stratix 5700 Switches Notes...
Страница 370: ...370 Rockwell Automation Publication 1783 UM007F EN P September 2016 Chapter 7 Configure Switch Features...
Страница 407: ...Rockwell Automation Publication 1783 UM007F EN P September 2016 407 Monitor the Switch Chapter 8...
Страница 409: ...Rockwell Automation Publication 1783 UM007F EN P September 2016 409 Monitor the Switch Chapter 8...
Страница 486: ...486 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix A DataTypes Notes...
Страница 494: ...494 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix B Port Assignments for CIP Data Notes...
Страница 540: ...540 Rockwell Automation Publication 1783 UM007F EN P September 2016 Appendix D Cables and Connectors Notes...
Страница 547: ......