3-64
Programming and Parameters
PowerFlex Digital DC Drive User Manual -
Publication 20P-UM001C-EN-P - July 2008
INPUT / OUTPUT
Analog I
nputs
1404
[Analog In1 Value]
Value of the signal at analog input 1. Units based on the value
set in Par 71 [Anlg In1 Config].
Default:
Min/Max:
Units:
Read Only
-/+20.00
V or mA
71
1405
[Analog In2 Value]
Value of the signal at analog input 2. Units based on the value
set in Par 76 [Anlg In2 Config].
Default:
Min/Max:
Units:
Read Only
-/+20.00
V or mA
76
1406
[Analog In3 Value]
Value of the signal at analog input 3. Units based on the value
set in Par 81 [Anlg In3 Config].
Default:
Min/Max:
Units:
Read Only
-/+20.00
V or mA
81
Anal
og Outputs
62
63
64
65
[Anlg Out1 Scale]
[Anlg Out2 Scale]
[Anlg Out3 Scale]
[Anlg Out4 Scale]
Scaling of the analog outputs.
Default:
Min/Max:
1.00
–/ +10.00
66
67
68
69
[Anlg Out1 Sel]
[Anlg Out2 Sel]
[Anlg Out3 Sel]
[Anlg Out4 Sel]*
Selects the source of the value that drives the analog output.
*This parameter is used to configure the analog output on the
I/O Expansion circuit board.
Options:
Default:
Default:
Default:
Default:
12 =
13 =
18 =
14 =
“Motor Speed”
“Motor Curr”
“Fld Current”
“Motor Volts”
(1) ±10V = 100% of Par 45 [Max Ref Speed].
(2) ±10V = ± 200% of Par 179 [Nom Mtr Arm Amps].
(3) ±10V = ± 200% of Par 179 [Nom Mtr Arm Amps] x Par 233 [Output Voltage].
(4) As a percentage of Par 1153 [Max Diameter].
File
Gr
oup
No.
Parameter Name & Description
See
page 3-2
for symbol descriptions
Values
Related
0 =
“Off” (Not used)
12 = “Motor Speed” (Par 121)
(1)
24 = “Field Ref” (Par 500)
1 =
“Spd Ref Out” (Par 385)
13 = “Motor Curr” (Par 199)
(2)
25 = “PID Output” (Par 774)
2 =
“Trim Ramp” (Par 42)
14 = “Motor Volts” (Par 233)
26 = “Out Volt Lvl” (Par 921)
3 =
“Ramp In” (Par 110)
15 = “Analog In 1” (Par 70)
27 = “Fld Cur Max” (Par 467)
4 =
“Ramp Out” (Par 113)
16 = “Analog In 2” (Par 75)
28 = “Filtered Spd” (Par 924)
(1)
5 =
“Spd Draw Out” (Par 1018)
17 = “Analog In 3” (Par 80)
29 = “Filtered Cur” (Par 928)
(2)
6 =
“Trim Speed” (Par 43)
18 = “Fld Current” (Par 234)
30 = “Output Power” (Par 1052)
(3)
7 =
“Spd Reg In” (Par 118)
19 = “UserDefined0” (Par 503)
31 = “Roll Diam” (Par 1154)
(4)
8 =
“Spd Reg Out” (Par 236)
20 = “UserDefined1” (Par 504)
32 = “Tension Ref” (Par 1180)
9 =
“Torque Ref” (Par 39)
21 = “UserDefined4” (Par 507)
33 = “Torque Curr” (Par 1193)
(2)
10 =
“Trim Torque” (Par 40)
22 = “UserDefined5” (Par 508)
34 = “Winder Ref” (Par 1217)
(1)
11 =
“Torq Reg In” (Par 41)
23 = “UserDefined6” (Par 509)
35 = “Active Comp” (Par 1213)
(2)