PowerFlex Digital DC Drive User Manual -
Publication 20P-UM001C-EN-P - July 2008
3-52
Programming and Parameters
UTI
L
ITY
Dia
gnosti
cs
1402 [Last Stop Source]
Displays the source that initiated the most recent stop sequence.
Default:
Options:
0 =
1 - 5 =
6 =
7 =
8 =
9 =
10 =
11 =
12 =
13 =
Read Only
“Pwr Removed”
“DPI Port 1-5”
“Reserved”
“Digital In”
“Fault”
“Not Enabled”
“Reserved”
“Jog”
“Selftune”
“Reserved”
1403 [Start Inhibits]
Displays the inputs currently preventing the drive from starting. For each bit, 1=Inhibit condition true and 0=Inhibit condition
false.
Fa
u
lt
s
263
[Clear Fault Que]
Allows you to clear the fault queue. Refer to Chapter 4
for information on clearing the fault
queue.
Default:
Options:
0 =
0 =
1 =
“Ready”
“Ready”
“Clr Flt Que”
1347 [Fault Clear]
Allows you to reset drive faults and/or clear the fault queue.
Default:
Options:
0 =
0 =
1 =
2 =
“Ready”
“Ready”
“Clear Faults”
“Clr Flt Que”
1348 [Fault Clr Mode]
Enables/Disables a fault reset (clear faults) attempt from any source.
This does not apply to fault codes which are cleared indirectly via
other actions.
Default:
Options:
1 =
0 =
1 =
“Enabled”
“Disabled”
“Enabled”
1349 [Status1 at Fault]
Captures and displays Par 381 [Drive Status 1] bit pattern at the time of the last fault. 0=Condition False, 1=Condition True.
381
1350 [Status2 at Fault]
Captures and displays Par 382 [Drive Status 2] bit pattern at the time of the last fault. 0=Condition False, 1=Condition True.
382
File
Gr
oup
No.
Parameter Name & Description
See
page 3-2
for symbol descriptions
Values
Related
Re
ser
ve
d
Re
ser
ve
d
DPI P
or
t 5
DPI P
or
t 4
DPI P
or
t 3
DPI P
or
t 2
DPI P
or
t 1
Di
gita
l In
Re
ser
ve
d
Star
tup Actv
Re
ser
ve
d
Stop Asser
td
Re
ser
ve
d
Enab
le
Ty
pe 2
Alar
m
Faul
t
Default
x
x
x
0
0
0
0
0
x
0
0
1
x
0
0
0
Bit
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
Spd
Re
f ID 3
Spd
Re
f ID 2
Spd
Re
f ID 1
Spd
Re
f ID 0
Lo
cal ID 2
Lo
cal ID 1
Lo
cal ID 0
At Speed
Fa
ul
te
d
Alar
m
Deceler
ating
Acceler
ating
Actu
al Dir
Comm
and Di
r
Activ
e
Ready
Default
0
0
0
0
1
1
1
0
1
0
0
0
1
1
0
0
Bit
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
A
uto T
uni
ng
Curr Limit
Stop
ping
Jo
ggin
g
Runni
ng
Activ
e
Ready
Default
x
x
x
x
x
x
x
x
x
0
0
0
1
1
0
0
Bit
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
Содержание PowerFlex series
Страница 1: ...USER MANUAL Firmware Version 1 006 2 001 PowerFlex Digital DC Drive ...
Страница 190: ...PowerFlex Digital DC Drive User Manual Publication 20P UM001C EN P July 2008 A 22 Supplemental Drive Information Notes ...
Страница 292: ...Index 24 PowerFlex Digital DC Drive User Manual Publication 20P UM001C EN P July 2008 ...
Страница 293: ......