1166 [Diam Preset 2]
Third preset starting diameter. The value of this parameter must be
set between the value of Pars 799 [Minimum Diameter] and 1153
[Max Diameter].
Default:
Min/Max:
Units:
1.00
0.00 / 32.00
m
799,
1153
1167 [Diam Preset 3]
Fourth preset starting diameter. The value of this parameter must be
set between the value of Pars 799 [Minimum Diameter] and 1153
[Max Diameter]. This parameter can be assigned to an analog input. If
an analog input is used, +10V corresponds to the value of [Max
Diameter] and the voltage corresponding to the minimum diameter =
10 x ([Minimum Diameter] / [Max Diameter]).
Default:
Min/Max:
Units:
1.00
0.00 / 32.00
m
799,
1153
1168 [Diam Preset Sel]
Selects the starting diameter for the Diameter Calculation function.
•
0 = Par 1164 [Diam Preset 0]
•
1 = Par 1165 [Diam Preset 1]
•
2 = Par 1166 [Diam Preset 2]
•
3 = Par 1167 [Diam Preset 3]
This parameter can also be set via two digital inputs programmed as
57 “Diam Preset0” and 58 “Diam Preset1”; the selection in this case is
carried out with binary logic.
Default:
Min/Max:
0
0 / 3
1164,
1165,
1166,
1167
1205 [Diam Inc Dec En]
This parameter It is used to improve system stability for winder/
unwinder applications. If this parameter is enabled and if applied to a
winder, the calculated diameter can never decrease; if applied to an
unwinder, the calculated diameter can never increase.
Default:
Options:
1 =
0 =
1 =
“Enabled”
“Disabled”
“Enabled”
1206 [Diam init filter]
Initial filter on the diameter calculation.
Default:
Min/Max:
Units:
100
0 / 5000
ms
1207 [Diam stdy delay]
The amount of time during which the value of Par 1206 [Diam init
filter] is kept active after the value defined in Par 1155 [Line Spd
Thresh] has been overcome.
Default:
Min/Max:
Units:
0
0 / 60000
ms
1155,
1206
W
inder Function
s
1171 [Variable J Comp]
Torque compensation due to the wound material as a percentage of
the drive rated current.
Default:
Min/Max:
Units:
0.00
0.00 / 199.99
%
1172 [Constant J Comp]
Compensation of the fixed section (motor, reducer, pin) as a
percentage of the drive rated current.
Default:
Min/Max:
Units:
1.00
– / +100.00
%
1173 [Materl Width Pct]
Width of the wound material as a percentage of the maximum width.
Default:
Min/Max:
Units:
100.00
0.00 / 100.00
%
1174 [Static Friction]
Compensation for static friction as a percentage of the drive rated
current.
Default:
Min/Max:
Units:
0.00
0.00 / 199.99
%
1175 [Dynamic Friction]
Compensation for dynamic friction as a percentage of the drive rated
current.
Default:
Min/Max:
Units:
0.00
0.00 / 199.99
%
File
Gr
oup
No.
Parameter Name & Description
See
page 3-2
for symbol descriptions
Values
Related
A
A
A
“Diam Preset1” “Diam Preset0” Selection
0
0
Par 1164 [Diam Preset 0]
0
1
Par 1165 [Diam Preset 1]
1
0
Par 1166 [Diam Preset 2]
1
1
Par 1167 [Diam Preset 3]
A
A
A
A
A
A
A
A
Содержание PowerFlex series
Страница 1: ...USER MANUAL Firmware Version 1 006 2 001 PowerFlex Digital DC Drive ...
Страница 190: ...PowerFlex Digital DC Drive User Manual Publication 20P UM001C EN P July 2008 A 22 Supplemental Drive Information Notes ...
Страница 292: ...Index 24 PowerFlex Digital DC Drive User Manual Publication 20P UM001C EN P July 2008 ...
Страница 293: ......