PowerFlex Digital DC Drive User Manual -
Publication 20P-UM001C-EN-P - July 2008
3-38
Programming and Parameters
APPLICA
T
IO
NS
PID Contr
o
l
782
[PID Target]
Parameter number to which the PID Output value will be written.
Default:
0 =
“Not Used”
Options:
786
[PID Source]
Parameter number from which the PID source value will be read.
Default:
0
“Not Used”
Options:
787
[PID Source Gain]
Gain of the input value to Par 786 [PID Source].
Default:
Min/Max:
1.00
–/+100.00
786
1046 [PID Accel Time]
Ramp acceleration time after the block PID offset.
Default:
Min/Max:
Units:
0.00
0.00 / 900.00
s
1047 [PID Decel Time]
Ramp deceleration time after the block PID offset.
Default:
Min/Max:
Units:
0.00
0.00 / 900.00
s
File
Gr
oup
No.
Parameter Name & Description
See
page 3-2
for symbol descriptions
Values
Related
A
0 =
“Not Used”
16 = “Reserved”
32 = “UsrDefined13” (Par 516)
1 =
“Cur Lim Pos” (Par 8)
17 = “Max Fld Pct” (Par 467)
33 = “UsrDefined14” (Par 517)
2 =
“Cur Lim Neg” (Par 9)
18 = “Reserved”
34 = “UsrDefined15” (Par 518)
3 =
“Reserved”
19 = “UsrDefined0” (Par 503)
35 = “Load Comp” (Par 698)
4 =
“Reserved”
20 = “UsrDefined1” (Par 504)
36 = “Out Volt Lvl” (Par 921)
5 =
“TrqRedCurLim” (Par 13)
21 = “UsrDefined2” (Par 505)
37 = “Reserved”
6 =
“Torque Ref” (Par 39)
22 = “UsrDefined3” (Par 506)
38 = “Speed Ratio” (Par 1017)
7 =
“Trim Torque” (Par 40)
23 = “UsrDefined4” (Par 507)
39 = “Reserved”
8 =
“Reserved”
24 = “UsrDefined5” (Par 508)
40 = “Reserved”
9 =
“Trim Ramp” (Par 42)
25 = “UsrDefined6” (Par 509)
41 = “Tension Red” (Par 1179)
10 = “Trim Speed” (Par 43)
26 = “UsrDefined7” (Par 510)
42 = “Reserved”
11 = “Reserved”
27 = “UsrDefined8” (Par 511)
43 = “Reserved”
12 = “Reserved”
28 = “UsrDefined9” (Par 512)
44 = “CloseLp Comp” (Par 1208)
13 = “Reserved”
29 = “UsrDefined10” (Par 513)
45 = “Reserved”
14 = “Adaptive Ref” (Par 183)
30 = “UsrDefined11” (Par 514)
46 = “Reserved”
15 = “Reserved”
31 = “UsrDefined12” (Par 515)
A
0 =
“Not Used”
16 = “SpdRegOutPct” (Par 236)
32 = “UsrDefined13” (Par 516)
1 =
“Cur Lim Pos” (Par 8)
17 = “Max Fld Pct” (Par 467)
33 = “UsrDefined14” (Par 517)
2 =
“Cur Lim Neg” (Par 9)
18 = “Fld Ref Pct” (Par 500)
34 = “UsrDefined15” (Par 518)
3 =
“CurLimPosOut” (Par 10)
19 = “UsrDefined0” (Par 503)
35 = “Load Comp” (Par 698)
4 =
“CurLimNegOut” (Par 11)
20 = “UsrDefined1” (Par 504)
36 = “Out Volt Lvl” (Par 921)
5 =
“TrqRedCurLim” (Par 13)
21 = “UsrDefined2” (Par 505)
37 = “Filt Trq Cur” (Par 928)
6 =
“Torque Ref” (Par 39)
22 = “UsrDefined3” (Par 506)
38 = “Speed Ratio” (Par 1017)
7 =
“Trim Torque” (Par 40)
23 = “UsrDefined4” (Par 507)
39 = “Spd Draw Out” (Par 1018)
8 =
“TorqueReg In” (Par 41)
24 = “UsrDefined5” (Par 508)
40 = “Roll Diam” (Par 1154)
9 =
“Trim Ramp” (Par 42)
25 = “UsrDefined6” (Par 509)
41 = “Tension Red” (Par 1179)
10 = “Trim Speed” (Par 43)
26 = “UsrDefined7” (Par 510)
42 = “Torq Cur Pct” (Par 1193)
11 = “Ramp In” (Par 110)
27 = “UsrDefined8” (Par 511)
43 = “Ten Ref Pct” (Par 1194)
12 = “Ramp Out” (Par 113)
28 = “UsrDefined9” (Par 512)
44 = “CloseLp Comp” (Par 1208)
13 = “Speed Reg In” (Par 118)
29 = “UsrDefined10” (Par 513)
45 = “Actual Comp” (Par 1213)
14 = “Adaptive Ref” (Par 183)
30 = “UsrDefined11” (Par 514)
46 = “W Reference” (Par 1217)
15 = “Arm Cur Pct” (Par 199)
31 = “UsrDefined12” (Par 515)
A
A
A
Содержание PowerFlex series
Страница 1: ...USER MANUAL Firmware Version 1 006 2 001 PowerFlex Digital DC Drive ...
Страница 190: ...PowerFlex Digital DC Drive User Manual Publication 20P UM001C EN P July 2008 A 22 Supplemental Drive Information Notes ...
Страница 292: ...Index 24 PowerFlex Digital DC Drive User Manual Publication 20P UM001C EN P July 2008 ...
Страница 293: ......