Specifications and Site Requirements
Electrical Specifications
Node Controller Hardware User Manual
65
Rockwell Automation Publication MMI-UM013B-EN-P - April 2020
Figure 4-11: NC-S Node Controller Electrical Connections, Controls, and Indicators
NOTICE
Connecting to the DC power connector on the NC-S node controller must be
done with the power supply off. Connecting with the power supply on can
cause a short circuit at the connector, which can damage the power supply or
any other equipment being powered by that power supply.
Table 4-1: NC-S Node Controller Electrical Connections
Label
Description
Connector Type
CONSOLE
External terminal
DE-9, Male
NET0
Ethernet - 10/100/1000 Base-Tx
(auto-MDIX, auto-negotiation)
RJ45, Female
NET1, NET2
not used
RJ45, Female
1-8
RS-422 motor communications
M8 Nano-Mizer, 4-Pin, Male
*
*
MagneMotion recommends that the odd number connectors be used for upstream connections and the even
number connectors be used for downstream connections.
POWER
24-48V DC ±10%, 10 W
M12 Eurofast, 4-Pin, Male
†
†
MagneMotion requires grounding the NC-S through the chassis ground connection on the power
connector.
Table 4-2: NC-S Node Controller Indicators
Label
Description
Indicator Type
POWER
ON – Indicates that DC power is on.
Green light
CONSOLE
NET 0
NODE CONTROLLER-S
NET 1
NET 2
1
2
3
4
POWER
5
6
7
8
Network
Console
RS-422 (8X)
Power
Power Indicator