Содержание Enwatch EK-44750C

Страница 1: ...t User Information 2 BeforeYou Begin 3 Parts List 3 Identify the Enwatch Board Issue 4 Identify the Power Supply 4 Exchange the Enwatch Boards and Power Supplies 5 Remove the Enwatch Board 5 Remove th...

Страница 2: ...installation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc with respect...

Страница 3: ...is not possible to ship the entire Enwatch enclosure system to a Rockwell Automation repair center IMPORTANT TheseinstructionsapplyonlytoEnwatchboardsP NEK 44750C EnwatchCSANIP N EK 44750CSANI must b...

Страница 4: ...F and earlier boards have a black heat sink in comparison to the Issue G and later boards that have a silver rectangle marked Traco Power Figure 1 Board Identification IdentifythePowerSupply The 12V D...

Страница 5: ...n and operation of this equipment andwhohavebeentrainedintherepairofthisequipmentandthehazards involved should install adjust operate or service and repair this equipment Readandunderstandthisdocument...

Страница 6: ...rd off of the standoffs to avoid static discharge or other contact that might damage the board and place it inside a static free package for proper storage Figure 4 Jumper and Screw Locations A B A B...

Страница 7: ...ires are connected to the grounding terminal strip disconnect them 3 Remove the four mounting base plate screws and washers circled 4 Lift the mounting base plate out of the Enwatch enclosure ATTENTIO...

Страница 8: ...moved in step 2 on page 7 InstalltheEnwatchBoard 1 Place the Enwatch board on the mounting base plate standoffs and replace the screws and washers removed in step 7 on page 6 2 Reconnect the Ethernet...