![Rockwell Automation CNMD180W0ENNNC1 Скачать руководство пользователя страница 89](http://html.mh-extra.com/html/rockwell-automation/cnmd180w0ennnc1/cnmd180w0ennnc1_user-manual_1475500089.webp)
Parameter Descriptions
3-63
Current state of the digital outputs.
Present operating temperature of the drive power section.
Accumulated percentage of drive overload. Continuously operating the drive over
100% of its rating will increase this value to 100% and cause a drive fault.
217
Dig Out Status
Range:
See figure 3.19
Default:
Read Only
Access:
2
Path:
Utility>Diagnostics
Inputs & Outputs>Digital Outputs
See also:
380-384
Figure 3.19 – Dig Out Status (276)
0
0
x
0
x
x
x
x
x
x
x
x
x
x
x
x
10
0
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1
=Output Energized
0
=Output De-energized
x =Reserved
Bit #
Digital Out1
Digital Out2
Digital Out3
218
Drive Temp
Range:
0 to 100.0 degC [0.1 degC]
Default:
Read Only
Access:
2
Path:
Utility>Diagnostics
See also:
219
Drive OL Count
Range:
0.0 to 100.0% [0.1%]
Default:
Read Only
Access:
2
Path:
Utility>Diagnostics
See also:
150
Содержание CNMD180W0ENNNC1
Страница 1: ...Instruction Manual Reach Drive User Manual Manufactured for DBT D2 3561 ...
Страница 206: ...B 4 DBT Reach Drive Manual ...
Страница 238: ...Appendix D 24 DBT Reach Drive User Manual ...
Страница 247: ......