DBT Reach Drive User Manual
Selects the source of the input controlling the Sleep-Wake function.
Defines the analog input level that will start the drive.
!
ATTENTION:
Enabling the Sleep-Wake function can cause unexpected
machine operation during the Wake mode. Failure to observe these
precautions can result in damage to the equipment and/or personal injury.
Table 3.2 – Conditions Required to Start Drive when Sleep-Wake is Enabled
1
2
3
Configured
Digital
Input(s)
After
Power-Up
After Fault
After Stop
Stop-CF Cmd
(HIM or
TermBlk)
Clear Faults Cmd
(TB or V*S Utilities)
HIM, TB, or Network Stop
Stop
Stop
Closed
Wake
Signal
Stop Closed
Wake Signal
Start/Run Cmd
4
Stop Closed
Stop Closed
Direct Mode: Analog Sig>Sleep Level
5
Invert Mode: Analog Sig<Sleep Level
5
Start/Run Cmd
Enable
Enable
Closed
Wake
Signal
Enable Closed
Wake Signal
Start/Run Cmd
4
Enable Closed
Wake Signal
Enable Closed
Direct Mode: Analog Sig>Sleep Level
5
Invert Mode: Analog Sig<Sleep Level
5
Start/Run Cmd
Run
Run For.
Run Rev.
Run
Closed
Wake
Signal
Run Cmd
4
Wake Signal
Run Closed
Wake Signal
Run Cmd
4
Wake Signal
1
When power is cycled, restart will occur if all conditions above are met.
2
When Sleep-Wake Mode is enabled, drive start will occur if all conditions above are met.
3
The Sleep-Wake function and Speed Reference may be assigned to the same analog input.
4
Start/Run Cmd must be cycled.
5
Signal does not have to be greater than Wake level.
179
Sleep-Wake Ref
Range:
1 = Analog In 1
2 = Analog In 2
Default:
2 = Analog In 2
Access:
1
Path:
Dynamic Control>Restart Modes
See also:
180
Wake Level
Range:
Sleep Level / 20.000 mA, 10.000 volts [0.001 mA, 0.001 V]
Default:
6.000 mA, 6.000 V
Access:
1
Path:
Dynamic Control>Restart Modes
See also:
181