Parameter Descriptions
3-109
Defines the value of the divisor for the Torque Ref A Sel (427) selection.
Defines the value of the multiplier for the Torque Ref B Sel (431) selection.
Provides an internal fixed value for Torque Setpoint when Torque Ref Sel is set to
Torque Setpt.
Defines the torque limit for the positive torque reference value. The reference will not
be allowed to exceed this value.
430
Torq Ref A Div
Range:
0.1 to 3276.7 [0.1]
Default:
1.0
Access:
1
Path:
Motor Control>Torq Attributes
See also:
53
FV
434
Torq Ref B Mult
Range:
-/+ 3276.7 [0.1]
Default:
1.0
Access:
1
Path:
Motor Control>Torq Attributes
See also:
53
FV
435
Torque Setpoint1
Range:
-/+ 800.0% [0.0%]
Default:
0.0%
Access:
1
Path:
Motor Control>Torq Attributes
See also:
53
FV
436
Pos Torque Limit
Range:
0.0 to 800.0% [0.1%]
Default:
200.0%
Access:
1
Path:
Motor Control>Torq Attributes
See also:
53
FV