![Rockwell Automation CNMD180W0ENNNC1 Скачать руководство пользователя страница 134](http://html.mh-extra.com/html/rockwell-automation/cnmd180w0ennnc1/cnmd180w0ennnc1_user-manual_1475500134.webp)
3-108
DBT Reach Drive User Manual
Selects the source of the external torque reference to the drive. How this reference is
used is dependent upon [Speed/Torque Mod].
Scales the upper value of the Torque Ref x Sel selection when the source is an analog
input.
Scales the lower value of the Torque Ref x Sel selection when the source is an analog
input.
427
431
Torque Ref A Sel
Torque Ref B Sel
Range:
0 = Torque Stpt1
1 = Analog ln 1
2 = Analog ln 2
3-17 = Reserved
18 = DPI Port 1
19 = DPI Port 2
20 = DPI Port 3
21 = DPI Port 4
22 = DPI Port 5
23 = Reserved
24 = Disabled
25 = Scale Block 1
26 = Scale Block 2
27 = Scale Block 3
28 = Scale Block 4
29 = Torque Stpt2
Default:
427: 0 = Torque Stpt1
431: 24 = Disabled
Access:
1
Path:
Motor Control>Torq Attributes
See also:
53
FV
428
432
Torque Ref A Hi
Torque Ref B Hi
Range:
-/+ 800.0% [0.1%]
Default:
100.0%
Access:
1
Path:
Motor Control>Torq Attributes
See also:
53
FV
429
433
Torque Ref A Lo
Torque Ref B Lo
Range:
-/+ 800.0% [0.1%]
Default:
0.0%
Access:
1
Path:
Motor Control>Torq Attributes
See also:
53