DBT Reach Drive User Manual
Sets the off delay time for the digital outputs. This is the time between the
disappearance of a condition and de-activation of the relay.
Inverts the selected digital output.
383
387
391
Digital Out1 OffTime
Digital Out2 OffTime
Digital Out3 OffTime
Range:
0.00 to 600.00 sec [0.1 sec]
Default:
0.00 sec
Access:
2
Path:
Inputs & Outputs>Digital Outputs
See also:
380
392
Dig Out Invert
Range:
See figure 3.36
Default:
See figure 3.36
Access:
2
Path:
Inputs & Outputs>Digital Outputs
See also:
Figure 3.36 – Dig Out Invert
0
0
x
0
x
x
x
x
x
x
x
x
x
x
x
x
10
0
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1
=Inverted
0
=Not Inverted
x =Reserved
Bit #
Factory Default Bit Values
Digital Out1
Digital Out2
Digital Out3