Technical Specifications - Interface Cables
Applications and Standard Lengths
Cat. No.
Descriptions
Standard Cable Lengths
m (ft)
2090-SCEP
x
-
x
Sercos fiber-optic plastic cables suitable for in-cabinet duty only. Connectors are provided at both
ends
0-1 (5.1 in.)
(1)
0-2 (7.1 in.)
0-3 (1.0)
1-0 (3.2)
(1) Only available as 2090-SCEP
x-x
.
3-0 (9.8)
5-0 (16.4)
8-0 (26.2)
10-0 (32.8)
15-0 (49.2)
20-0 (65.5)
25-0 (82.0)
32-0 (105.0)
2090-SCNP
x
-
x
Sercos fiber-optic plastic cables suitable for On-Machine™ duty. Connectors are provided at both
ends
2090-SCVP
x
-
x
Sercos fiber-optic plastic cables suitable for outdoor and conduit duty. Connectors are provided at
both ends
2090-SCVG
x
-
x
Sercos fiber-optic glass cables suitable for outdoor and conduit duty. Connectors are provided at
both ends
50-0 (164.2)
100-0 (328.3)
150-0 (492.5)
200-0 (656.7)
2090-S-BLHD
Sercos fiber-optic cable bulkhead adapter (2 per pack)
1585J-M8CBJM-
x
(2)
(2) Refer to the Industrial Ethernet Media Brochure, publication
, for product specifications.
Double-ended (shielded) Ethernet cables for use when programming the safety configuration and
the Logix 5000™ EtherNet/IP network module
OM15 = 0.15 (6 in.)
OM3 = 0.3 (1.0)
OM4 = 0.4 (1.3)
OM6 = 0.6 (2.0)
1 (3.2)
2 (6.6)
5 (16.4)
10 (32.8)
1585J-M8UBJM-
x
Double-ended (shielded) Ethernet cables for use in high-flex applications
1585J-M8CB-
x
Single-ended (shielded) Ethernet cables for use when programming the safety configuration and
the Logix 5000 EtherNet/IP network module
2 (6.6)
5 (16.4)
10 (32.8)
1585J-M8CC-H
RJ45 insulation displacement connector (IDC) for use when making your own cables
100 (328)
300 (984)
600 (1968)
1585J-C8CB-S
xxx
Shielded Ethernet (bulk) cable for use when making your own cables
2090-CCMDSDS-48AA
xx
Kinetix 3 control interface cable for drive-to-drive configurations
01 = 1.0 (3.2)
P3 = 0.3 (0.98)
2090-CCMPCDS-23AA
xx
Kinetix 3 serial interface cable to personal computer
01 = 1.0 (3.2)
03 = 3.0 (9.8)
2090-CCMCNDS-48AA
xx
Kinetix 3 control interface cable to MicroLogix controller
2090-CCMUSDS-48AA
xx
Kinetix 3 control interface for drive-to-1203-USB converter
2090-DAIO-D50
xxx
Kinetix 3 control interface I/O cable (flying leads)
2090-CS0DSDS-AA
xx
Kinetix 6200/6500 interface cables for I/O and cascading safe torque-off signals from drive-to-
drive
02 = 0.2 (7.1 in.)
03 = 0.3 (1.0)
10 = 1.0 (3.2)
1202-C02
Drive-to-drive safety cable for connecting single-wide Kinetix 6000 axis modules
200 mm (7.9 in.)
1202-C03
Drive-to-drive safety cable for connecting double-wide Kinetix 6000 axis modules
350 mm (13.8 in.)
1202-C10
Drive-to-drive safety cable for connections between two Kinetix 6000 power rails, two Kinetix 7000
drives, or from the Kinetix 6000 power rail to Kinetix 7000 drive
1050 mm (41.3 in.)
1202-C30
Drive-to-drive safety cable for any connections requiring additional cable length within the system
enclosure.
30 (98.4)
2090-XXNRB-10F0P5
Resistive Brake Module (RBM) to Kinetix 6000 and Kinetix 6200/6500
drives
10 AWG
0.5 (1.6)
2090-XXNRB-8F0P6
8 AWG