Rockwell Automation Publication 6300P-UM001B-EN-P - March 2021
19
Chapter 2 Install the Panel PC
Connect DC Power
Operate the panel PC in an industrial or control room environment, which
uses some form of power isolation from the public, low-voltage mains.
All VersaView DC powered models require a safety extra low voltage (SELV)
power supply. The power supply is internally protected against reverse
polarity.
To minimize ground loop currents and noise, Allen-Bradley recommends that
DC powered models use only one grounded connection. See
for the ground connection on these models.
Follow these steps to connect the computer to a DC power source.
Install the DC Power Connector Assembly
This connector assembly provides strain relief for the DC power wires by
reducing their movement. To assemble and attach the connector assembly,
perform the following steps.
1.
Remove the DC terminal block from the computer chassis.
2. Open the power connector assembly kit that ships with the computer
).
3. Insert the cable tie through the slots of the appropriate connector half
4. Strip the end of each DC power wire to the length in
.
5. Insert each stripped end into the DC terminal block as shown in
ATTENTION:
When you connect power to the computer for the first time, these
actions occur:
• The default UEFI setting automatically starts the computer after it is plugged into a
power source.
• For VersaView 6300P panel PCs with a Microsoft Windows operating system (OS),
you must read and accept an End User Setup procedure.
Do not disconnect power from the system until after the Windows Setup
Procedure is completed. If power is disconnected during this procedure, it can
result in a corrupted system image.
ATTENTION:
For VersaView 6300P panel PCs with a Windows OS, perform the
following:
• Supply the computer with its own disconnect. Use an uninterruptible power source
(UPS) to help protect against unexpected power failure or power surges.
• Always shut down the Windows OS before you disconnect power to the computer to
minimize performance degradation and operating system failures.
You need the following tools for this installation:
• Adjustable torque screwdriver with M2 and M3 flat-blade screw bits
• Wire stripper, cutter, and crimper tool
• Cutting pliers
IMPORTANT
DC power wires must be of stranded copper, certified for at least 85 °C
operation, and sized according to
IMPORTANT
The DC terminal block in the photos is only for illustrative purposes.
Your DC terminal block can differ in size, shape, and color to what is
shown in the photos.
Содержание Allen-Bradley VersaView 6300P Series
Страница 1: ...VersaView 6300P Panel PCs Catalog Number 6300P User Manual Original Instructions ...
Страница 8: ...8 Rockwell Automation Publication 6300P UM001B EN P March 2021 Preface Notes ...
Страница 12: ...12 Rockwell Automation Publication 6300P UM001B EN P March 2021 Chapter 1 About the Panel PC Notes ...
Страница 24: ...24 Rockwell Automation Publication 6300P UM001B EN P March 2021 Chapter 3 Operate the Panel PC Notes ...
Страница 42: ...42 Rockwell Automation Publication 6300P UM001B EN P March 2021 Chapter 6 Troubleshoot the System Notes ...