26
Rockwell Automation Publication 20B-IN025C-EN-P - October 2015
Chapter 2
Basic Component Removal Procedures
Blower Control Panel
See Chapter 1 - Component Diagrams and Torque Specifications on page
locate the component detailed in these instructions.
Remove Components
1.
Read and follow the Safety Precautions on page
Steps on page
.
2.
Disconnect the three wires (red, white, and blue) at the top of the blower
fuse block.
3.
Label and remove all wiring to TB9.
4.
Remove the two screws that connect the Blower Control Panel to the
Main Control Panel.
NOTE:
These screws are already removed if the Main Control Panel has
been removed.
5.
Remove the two screws that connect the Blower Control Panel to the
Stacking Panel.
6.
Carefully set the Blower Control Panel aside.
Install Components
1.
When instructed for the component you are replacing, reinstall the Blower
Control Panel in the reverse order of removal.
2.
See page
28
for reinstalling wires to TB9.
3.
Torque panel mounting screws to 2.9 N•m (26 lb•in).
4.
Replace all safety shields and enclosure covers before applying power to the
drive.
Red White Blue
Screws (2) to connect to
Main Control Panel
Screws (2) to connect to Stacking Panel
Содержание Allen-Bradley PowerFlex 700 Drive Frame 9
Страница 1: ...PowerFlex 700 Drive Frame 9 Components Replacement Catalog Numbers 20B Installation Instructions...
Страница 4: ...4 Rockwell Automation Publication 20B IN025C EN P October 2015 Summary of Changes Notes...
Страница 8: ...8 Rockwell Automation Publication 20B IN025C EN P October 2015 Table of Contents...
Страница 92: ...92 Rockwell Automation Publication 20B IN025C EN P October 2015 Appendix A History of Changes Notes...
Страница 93: ......