Test Safety Functions
To test the safety functions of the second generation MobileView 2711T terminal, perform the
following steps.
1.
Connect the safety terminations for the E-stop and 3-position enable switch to the IP65
junction box.
2.
Apply power to the IP65 junction box.
3.
Attach the 22-pin MobileView connection cable to the IP65 junction box as shown on
4.
Test the E-stop push button and the enabling switch to verify that each safety function is
operating properly. Verify that the machine or plant operation stops when the button is
pushed.
IMPORTANT
If the second generation MobileView 2711T terminal is properly connected to the IP65
junction box, a status indicator light on the terminal next to the E-stop is illuminated
green.
When a second generation MobileView 2711T terminal is powered up, a dark screen is
present for several seconds between the start-up screen and the next available screen.