Rockwell Automation Publication 2711T-QS002C-EN-P - March 2019
27
Second Generation MobileView Tethered Operator Terminal
Connected/Disconnected Timer State
A second generation MobileView terminal or a black bridge connector must be connected to the
IP65 junction box. When you disconnect one to connect the other, the IP65 junction box
recognizes the disconnection and enters a timer state, when the operator has a maximum of 10
seconds to reconnect a device.
During this disconnected time, the E-stop of the IP65 junction box is bypassed until a
MobileView terminal with an unactivated E-stop push button or a black bridge connector is
connected.
Bride active
A black, 22-pin bridge connector is connected.
E-stop
The E-stop push button on the second generation MobileView terminal has been activated.
Error state
The E-stop push button on the connected, second generation MobileView terminal and the retrieved E-stop
in the IP65 junction box memory are not the same. In this case, the E-stop push button of the connected
MobileView terminal is unactivated but the saved, retained E-stop in the IP65 junction box memory is
activated. Therefore, the E-stop push button on the MobileView terminal must be activated and then
unlocked to reset the IP65 junction box.
If
Then
The connected, second generation MobileView terminal
has an illuminated E-stop push button that is
unactivated
(1)
(1)
You must first configure an IP65 junction box to recognize an illuminated E-stop push button on a second generation MobileView terminal. For
more information, see
.
The E-stop push button is recognized by the IP65 junction box and it
is illuminated.
The connected, second generation MobileView terminal
has an illuminated E-stop push button that is properly
configured but activated
The E-stop push button on the second generation MobileView
terminal must be deactivated and reset before the IP65 junction box
returns to the normal state mentioned in
A black bridge connector is being connected
The black bridge connector must be connected within 10 seconds for
the IP65 junction box to recognize the device and enter the bridge
active state mentioned in
Reconnect Power to IP65 Junction Boxes on
.
No second generation MobileView terminal or black
bridge connector is connected within 10 seconds
The IP65 junction box timer state times out and an E-stop is
triggered.
State
Description