106
Rockwell Automation Publication 2080-UM002L-EN-E - November 2021
Chapter 7 Motion Control
Table 12 - Dynamics Parameters
Parameter
Values
Start/Stop Velocity
(1)
(2)
(1) The parameter is set as REAL (float) value in Connected Components Workbench. To learn more about conversions and rounding of
REAL values, see
Real Data Resolution on page 108
(2) The formula for deriving rpm to user unit, and vice versa:
The range is based on Motor and Load parameters (See
Range
1…100,000 pulse/sec
Default
: 300 rpm
For example, you can configure the value from 0.005…500 mm/s for 200 pulses per
revolution and units of 1 mm per revolution.
(3)
Rpm value is automatically populated when a value in user units is specified, but the
user can also initially enter an rpm value.
Start/stop velocity should not be greater than maximum velocity.
(3) To convert from parameter value from pulse to user units:
Start/Stop Velocity in rpm
(1) (2)
Max Velocity
(1) (2)
The range is based on Motor and Load parameters (See
Range: 1…10,000,000 pulse/sec.
Default: 100,000.0 pulse/sec
Max Acceleration
(1)
The range is based on Motor and Load parameters (See
Range
: 1…10,000,000 pulse/sec
2
Default
: 10,000,000 pulse/sec
2
Max Deceleration
(1)
The range is based on Motor and Load parameters (See
Range
: 1…100,000 pulse/sec
2
Default
: 10,000,000 pulse/sec
2
Max Jerk
(1)
The range is based on Motor and Load parameters (See
Range
: 0…10,000,000 pulse/sec
3
Default
: 10,000,000 pulse/sec
3
Emergency Stop Profile
Defines stop type, velocity, deceleration, and jerk values.
Stop Type
Set as Deceleration Stop (default) or Immediate Stop.
Stop Velocity
(1)
The range is based on Motor and Load parameters (See
Range
: 1…100,000 pulse/sec
Default
: 300 rpm
Stop Deceleration
(1)
The range is based on Motor and Load parameters (See
Range
: 1…10,000,000 pulse/sec
Default
: 300.0 rpm
2
Stop Jerk
(1)
The range is based on Motor and Load parameters (See
Range
: 0...10,000,000 pulse/sec
3
Default
: 0.0 rpm
3
(Disabled)
A red border on an input field indicates that an invalid value has been
entered. Scroll over the field to see tooltip message that will let you know
the valid value range for the parameter. Supply the valid value.
v (in rpm) =
v (in user unit/sec) x 60 s
travel per revolution (in user unit)
Value in user unit = Value in pulse x
Travel per revolution
Pulse per revolution
Содержание Allen-Bradley Micro850
Страница 12: ...12 Rockwell Automation Publication 2080 UM002L EN E November 2021 Preface Notes ...
Страница 36: ...36 Rockwell Automation Publication 2080 UM002L EN E November 2021 Chapter 2 About Your Controller Notes ...
Страница 44: ...44 Rockwell Automation Publication 2080 UM002L EN E November 2021 Chapter 3 Install Your Controller Notes ...
Страница 120: ...120 Rockwell Automation Publication 2080 UM002L EN E November 2021 Chapter 7 Motion Control Notes ...
Страница 156: ...156 Rockwell Automation Publication 2080 UM002L EN E November 2021 Chapter 9 Controller Security Notes ...
Страница 184: ...184 Rockwell Automation Publication 2080 UM002L EN E November 2021 Chapter 10 Using microSD Cards Notes ...
Страница 226: ...226 Rockwell Automation Publication 2080 UM002L EN E November 2021 Appendix C Quickstarts 10 Click Finish to complete ...
Страница 248: ...248 Rockwell Automation Publication 2080 UM002L EN E November 2021 Appendix C Quickstarts Notes ...
Страница 262: ...262 Rockwell Automation Publication 2080 UM002L EN E November 2021 Appendix D User Interrupts Notes ...
Страница 272: ...272 Rockwell Automation Publication 2080 UM002L EN E November 2021 Appendix E Troubleshooting Notes ...