Kinetix MMA Asynchronous Main Motors Installation Instructions
Figure 1 - Minimum Mounting Clearances
Feedback
All Kinetix MMA main motors are supplied with an encoder at the non-drive end of the motor. See the
for additional information. See Kinetix
Rotary Motion Specifications Technical Data, publication
and Kinetix Rotary and Linear Motion Accessories, publication
, to find environmentally
sealed connectors and cables compatible with these motors. See the Knowledgebase article:
Kinetix MMA Frequently Asked Questions
, for additional information.
Cables
Your motor requires environmentally sealed connectors and cables as standard equipment. Motor feedback, power, and brake functions all have separate cables and are
terminated in the motor terminal box. Rockwell Automation recommends a feedback cable for the Kinetix MMA main motors, but this feedback cable is ordered and shipped
separately from the motor. The customer must supply their own brake and power cables. See
Cable and Connector Descriptions
for additional information. See the Knowledgebase article:
Kinetix MMA Frequently Asked Questions
, for additional information.
Shaft Seals
Your motor requires a shaft seal as standard equipment. The shaft seal is required on the motor shaft, near the front motor bearing, to protect the motor from significant
amounts of fine dust or fluids, such as lubrication oil from a gearbox. See
for additional information.
See
Environmental Ratings on page 58
for the IP rating for your motor.
Motor Cat. No.
A mm (in.)
B mm (in.)
C mm (in.)
D mm (in.)
E mm (in.)
(1)
(1)
Dimension E is the required clearance to reposition a radial blower to the left or right.
Dimensions C and D also apply to a repositioned radial blower.
MMA-B080
xxx
40 (1.56)
30 (1.18)
50 (1.97)
30 (1.18)
—
MMA-B100
xxx
50 (1.97)
40 (1.56)
70 (2.76)
40 (1.56)
—
MMA-B132
xxx
80 (3.15)
60 (2.36)
90 (3.54)
60 (2.36)
344 (13.54)
MMA-B160
xxx
80 (3.15)
60 (2.36)
90 (3.54)
60 (2.36)
408 (16.06)
MMA-B180
xxx
120 (4.72)
80 (3.15)
140 (5.51)
80 (3.15)
473 (18.62)
MMA-B225
xxx
120 (4.72)
100 (3.93)
140 (5.51)
100 (3.93)
546 (21.50)
IMPORTANT
Based on mounting orientation, there may be a need for
modifications to the mounting clearances to access the
air inlet filter, terminal box, blower, or other
maintenance items.
E
D
D
D
A
B
B
B
D
D
D
C
D
D
D