Publication 2094-UM001A-EN-P — September 2006
Configure and Startup the Kinetix 6000 Drive System
129
3.
Click OK.
The New Module dialog opens.
a. Name the module.
b. Set the Node address.
Set the node address in the software to match the node setting on
the drive. Refer to Configure the IAM/AM, Step 2, on page 120.
c. Select an Electronic Keying option.
d. Check the box Open Module Properties.
4.
Click OK.
5.
Select the Associated Axes tab.
6.
Click the New Axis button.
The New Tag dialog opens.
7.
Add the axis.
a. Name the axis.
b. Select AXIS_SERVO_DRIVE as the Data Type.
8.
Click OK.
The axis appears under the Ungrouped Axes folder in the explorer
dialog.
9.
Assign your axis to the node address (as shown in the dialog
below).
Содержание Allen-Bradley Kinetix 6000
Страница 8: ...Publication 2094 UM001A EN P September 2006 8 Table of Contents...
Страница 18: ...Publication 2094 UM001A EN P September 2006 18 Start...
Страница 118: ...Publication 2094 UM001A EN P September 2006 118 Connecting the Kinetix 6000 Drive System...
Страница 144: ...Publication 2094 UM001A EN P September 2006 144 Configure and Startup the Kinetix 6000 Drive System...
Страница 168: ...Publication 2094 UM001A EN P September 2006 168 Removing and Replacing the Kinetix 6000 Drive Modules...
Страница 190: ...Publication 2094 UM001A EN P September 2006 190 Specifications and Dimensions...
Страница 256: ...Publication 2094 UM001A EN P September 2006 256 Integrating Resistive Brake Modules with Kinetix 6000 Drives...
Страница 265: ...Publication 2094 UM001A EN P September 2006 265 Notes...
Страница 266: ...Publication 2094 UM001A EN P September 2006 266 Notes...
Страница 267: ...Publication 2094 UM001A EN P September 2006 267 Notes...