GuardShield Type 4 and GuardShield Remote Teach

system. The following Operating modes if configured cause the light 

curtain to fault;

• EDM
• Start and restart interlock 

Power must be cycled and the segment pair must be retaught to 

deactivate the mode.

Table 40 - Teach-in Procedure Function

The doors on the transmitter and receiver must be closed for the 

GuardShield light curtain to operate.

Troubleshooting Guide

The light curtain conducts an internal self-test after startup. If an error 

occurs, an appropriate signal combination is sent through the status 

indicators to the transmitter and receiver.

Table 41 - Error Descriptions

Figure 42 - Status Indicator at Transmitter (Tx) and Receiver (Rx)

Table 43 - System Status Indicators

IMPORTANT

Configuration of the EDM in a middle or end segment causes 

an EDM fault in that configured segment even if EDM is also 

configured and functions in the Host segment. Interruption of 

the middle or end segment, which has EDM also configured, 

causes the middle or end segment to go to a lock out 

condition. That condition cannot be reset without cycling 

power and reconfiguring the middle or end segment without 

the non-allowed configuration.
Configure the start or restart interlock in the middle or end 

segment causes a fault in the middle or end segment, which 

has that Operating mode configured. The status indicator 

shows a “Waiting for reset” fault, which cannot be reset even 

if the Host segment is also configured for the start or restart 

interlock. Due to the lack of an internal reset line in the 

middle or end segment, it is not possible to reset the middle 

or end segment before resetting the Host segment.

Step 1

Open the cover of the end cap 

Receiver: red status indicator flashes (OSSD OFF)

Transmitter: orange status indicator flashes (POWER ON). See 

Figure 42 on 

page 18

.

Step 2

Select the desired DIP switch setting.

Step 3

Press and hold the Teach button. The yellow status indicator starts flashing at 

10 Hz (10x per second):

RX: Blanking indicator

TX: Emitting indicator

Step 4

After five seconds, the status indicator stops flashing. After the indicator stops 

flashing, release the teach button within two seconds. After three flashes of the 

yellow status indicator, the function is activated.

Step 5

Close and secure the cover. The indicator stops flashing.

IMPORTANT

If the GuardShield light curtain teach procedure is not 

properly completed, the unit remains in the previous 

operating mode.
Once the teach function is completed and the door that is 

secured, verify that the operating mode has changed to the 

intended mode.

Condition No.

Error Description

Action

8

Internal fault, receiver

• Check configuration of transmitter 

and receiver

• Replace receiver

9

Internal fault, transmitter

• Check configuration of transmitter 

and receiver

• Check protective field transmitter/

receiver

• Check connections transmitter/

receiver 

• Exchange transmitter

10

External fault 

• Check connections of OSSD outputs 

for short circuit a24V DC and 
GND (cable, connected devices)

• Exchange receiver

11

External fault (MPCE/EDM error)

The function 

Relay monitoring

 

is activated and after clearing 

the OSSD the input Relay 

monitoring does not recognize a 

change of state.

• Check connection Relay monitoring
• Check connected relay for closed 

contact (if OSSD ON—input Relay 
monitoring must have GND level, if 
OSSD OFF—input Relay monitoring 
must have +24V)

• Switch on only after POWER OFF/ON

12

Configuration mode (Receiver)

• Cover for DIP switch setting at the 

receiver is open 

13

Configuration mode 

(Transmitter)

• Cover for DIP switch setting at 

transmitter is open 

Receiver

Transmitter

OSSDs OFF

Blanking

Emitting

OSSDs ON

Interlock

Alignment

POWER ON

Condition No.

Receiver Status Indicators

Transmitter Status Indicators

OSSDs

OFF

Red

OSSDs

ON

Green

Blanking

Yellow

Alignment

Amber

Interlock

Yellow

Power

On

Amber

Emitting

Yellow

1

OFF

ON

OFF

OFF

OFF

ON

ON

2

ON

OFF

OFF

OFF

OFF

ON

ON

Содержание Allen-Bradley Guardmaster GuardShield Remote Teach

Страница 1: ...nt of operation and perimeter and access detection It is a self contained two box Type 4 electro sensitive protective equipment ESPE with DIP switch selectable operating modes The GuardShield light cu...

Страница 2: ...e is a Type 4 ESPE as defined by IEC 61496 1 and IEC 61496 2 Therefore it is allowed for use with controls In safety Cat 4 up to PLe in accordance with EN ISO 13849 1 SIL CL3 in accordance with EN 620...

Страница 3: ...ation removes the possibility of operation by a person working inside the hazardous area The statutory and local rules and regulations must be observed when installing and using the device Restart int...

Страница 4: ...segments The individual segments can have mixed resolutions for instance 14 mm and 30 mm 1 18 in as long as the pairs have the same protective heights and resolutions Cascade segments can be used as...

Страница 5: ...eration is through DIP switch setting in the GuardShield light curtain receiver see Table 37 on page 17 EDM is not available in the middle and end segments of a cascading GuardShield light curtain sys...

Страница 6: ...d activated FloatingBlanking The floating blanking mode of operation is activated through DIP switch settings that are located in the GuardShield light curtain receiver see Receiver Factory Settings o...

Страница 7: ...ing Blanking Symbol Description Beam not interrupted Beam interrupted Beamisactivated forFixedBlanking andnot interrupted Beamisactivated forFixedBlanking andinterrupted Case 1 2 3 4 5 6 7 8 Infrared...

Страница 8: ...ime that is measured at approximately the 90 position of the crankshaft rotation Resolution Protective Height Number of Beams ResponseTime w o Coding ResponseTime w Coding 14 0 55 160 6 3 16 20 ms 30...

Страница 9: ...object sensitivity of the safety light curtain Object sensitivity resolution is the smallest diameter object which is detected anywhere in the sensing field Example for US In a perpendicular safety l...

Страница 10: ...between sender and receiver Figure 12 Minimum Distance from Reflecting Surfaces Howto DeterminetheMinimumDistancefromtheReflecting Surfaces Determine the distance D m sender receiver Read the minimum...

Страница 11: ...L ALAT and mounting bracket 450L ALAT C is offered as an accessory for aligning the GuardShield light curtain without Integrated Laser Alignment see Laser Alignment Tool on page 35 AlignmentProceduref...

Страница 12: ...ective solution is to interconnect an additional light curtain in series to the vertical pair Select a Host or cascade pair of GuardShield safety light curtains with a protective height and resolution...

Страница 13: ...ry to use additional brackets see Figure 23 to mount the GuardShield light curtain at a proper safety distancefromthe machinery hazard Forapplications with shock and or vibrations also see Table 66 Fi...

Страница 14: ...Low Voltage Directives The grounded conductor of the power supply device must be connected to a grounded conductor PE The maximum deviation of the voltage levels is 24V DC 20 EDMConnection See Relay...

Страница 15: ...ter Brown 1 24V DC White 2 No Connection Blue 3 0VDC Black 4 MachineTestSignal Receiver Connection Face View of Female DC Micro Color PinNo Signal Receiver White 1 Auxiliary Output Brown 2 24V DC Gree...

Страница 16: ...le IMPORTANT IfMPCE EDMisactivated intheGuardShieldlightcurtain the application requires asafety contactor If MPCE EDMis not used K1 K2 can bestandardcontactors M 24V DC 24V Ground SENDER OSSD 1 OSSD...

Страница 17: ...ton Switch Switch Function Default Setting Description 1 Mode Activation Combination activates oneofthe followingmodes Guardonly startinterlock restart interlock ON Guard Only see Table 39 on page17 2...

Страница 18: ...tep 2 Selectthe desiredDIPswitch setting Step 3 Press and hold theTeach button Theyellow status indicator startsflashing at 10 Hz 10x per second RX Blanking indicator TX Emitting indicator Step 4 Afte...

Страница 19: ...set mode in start orrestart interlock aligned 5 Fixed blankingmode aligned not ininterlock 6 FloatingorFloating Fixed Blanking mode aligned not in interlock 7 Transmitter testinputactive pin 4 8 Inter...

Страница 20: ...llowinginspection Improperinspectioncanlead to serious or even deadly injury 1 Approach to hazardous machineparts mustonly bepossiblethrough passagethrough the protectivefield ofGuardShieldlight curta...

Страница 21: ...XX M or4K R 02 M representedManchester NH replacedby 4KforMonterrey Mexico J 2004 K 2005 L 2006 M 2007 N 2008 P 2009 R 2010 S 2011 T 2010 U 2013 V 2014 W 2015 Y 2016 Z 2017 Rockwell Automation Inc 12...

Страница 22: ...ON state OSSDOFF state Blanking Alignment Interlock Constant ON whenOSSDis in ON state greenindicator Constant ON whenOSSDis in OFF state redindicator Lights upatinterruptionofprotective fieldor if f...

Страница 23: ...itter Receiver Resolution mm in No of Beams Protective Heights mm in PairWeight kg lb Finger Resolution 440L P4JL0320YD 440L T4JL0320YD 440L R4JL0320YD 14 0 55 32 320 12 59 5 17 2 35 440L P4JL0480YD 4...

Страница 24: ...35 440L C4J0480YD 440L G4J0480YD 440L F4J0480YD 14 0 55 48 480 18 89 6 59 2 99 440L C4J0640YD 440L G4J0640YD 440L F4J0640YD 14 0 55 64 640 25 19 7 99 3 62 440L C4J0800YD 440L G4J0800YD 440L F4J0800YD...

Страница 25: ...8 80 1600 62 99 19 28 8 75 Sensor Pair Transmitter Receiver Resolution mm in No of Beams Protective Heights mm in Pair Weight kg lbs Finger Resolution 440L C4JL0320YA 440L G4JL0320YA 440L F4JL0320YA 1...

Страница 26: ...ransmitter R Receiver Standard C Host Pair G Host Transmitter F Host Receiver Cascading Bulletin Number 0160 Protective Height 0320 0480 0960 1440 0640 1120 1600 0800 1280 1760 R Remote Teach Pigtail...

Страница 27: ...28 5 632 1 5 24 9 0 06 440L 4 0640Y 640 0 5 25 2 0 02 756 29 8 792 1 5 31 2 0 06 440L 4 0800Y 800 0 6 31 5 0 02 916 36 1 952 1 5 37 5 0 06 440L 4 0960Y 960 0 6 37 8 0 02 1076 42 4 1112 1 5 43 8 0 06...

Страница 28: ...9 686 26 6 712 28 0 440L 1 4 2 L0640Y 3 640 25 2 836 32 9 872 34 3 440L 1 4 2 L0800Y 3 800 31 5 996 39 2 103 4 1 440L 1 4 2 L0960Y 3 960 37 8 1156 45 5 119 4 7 440L 1 4 2 L1120Y 3 1120 44 1 1316 51 8...

Страница 29: ...supplied with each GuardShield Remote Teach light curtain receiver The GuardShield Remote Teach Box light curtain system consists of Remote teach key selector switch box with mounting plate and two k...

Страница 30: ...vation and configuration of a monitored fixed blanked area within the GuardShield light curtain protective height Make any additional DIP switch settings now RemoteTeachProcedure 1 Position object in...

Страница 31: ...stem 1600 mm 63 in protectiveheight 30 mm 1 18 in resolution 440L S4K1760YR GuardShield RemoteTeachlight curtain system 1760 mm 69 3 in protectiveheight 30 mm 1 18 in resolution Catalog Number Descrip...

Страница 32: ...GWS0800 440L AGWS0960 440L AGWS1120 440L AGWS1280 440L AGWS1440 440L AGWS1600 440L AGWS1760 GuardShield light curtainTest Rod 14 mm 450L AT 14 GuardShield light curtainTest Rod 30 mm 450L AT 30 GuardS...

Страница 33: ...0 mm 70 86 in 15 m 49 21 ft 1896 1840 1872 1940 8 x 13 50 1 96 73 2 87 A Ls L B A A Section A A 120 114 4 48 13 3 5 24 35 1 37 54 2 12 44 4 1 74 75 2 95 2 5 0 09 6 5 0 25 4 5 0 17 10 5 0 41 Model No S...

Страница 34: ...40L P2K 0480YD 440L P4A2500YD 440L AM0750600 440L AM1250600 440L P4 0640Y 440L P2K 0640YD 440L AM0750750 440L AM1250750 440L P4 0800Y 440L P2K 0800YD 440L AM0750900 440L AM1250900 440L P4 0960Y 440L P...

Страница 35: ...GuardShield light curtain transmitter host patchcord has 4 pin DC micro over molded quick disconnect connectors that are offered in lengths of 0 3 m 0 98 ft 1 m 3 28 ft and 2 m 6 56 ft The GuardShiel...

Страница 36: ...CDM 1 5 pin M12 patchcord 1 3 28 5 6 7 8 4 3 1 2 889D F5ACDM 2 5 pin M12 patchcord 2 6 56 889D F5ACDM 5 5 pin M12 patchcord 5 16 4 889D F5ACDM 10 5 pin M12 patchcord 10 32 81 IMPORTANT Transmitter and...

Страница 37: ...o and including SIL cl3 in accordance with EN 61508 and EN 62061 Performance Level e and Category 4 in accordance with ISO 13849 1 ESPE Type 4 safety light curtain in accordance with EN IEC 61496 Comp...

Страница 38: ...38 Rockwell Automation Publication 440L IN012A EN P November 2017 GuardShieldType 4and GuardShield RemoteTeach Notes...

Страница 39: ...Rockwell Automation Publication 440L IN012A EN P November 2017 39 GuardShieldType 4andGuardShield RemoteTeach Notes...

Страница 40: ...ent complete the How Are We Doing form at http literature rockwellautomation com idc groups literature documents du ra du002_ en e pdf Technical Support Center KnowledgebaseArticles How toVideos FAQs...

Отзывы: