Use the Multifunctional Access Box in an Integrated Safety Controller-based System
10. Click Disable BOOTP/DHCP.
The module now uses the assigned configuration and will no longer issue
DHCP requests.
Restoring the Module to
DHCP Mode
When the IP Address of the Module Is Known
Use a BootP/DHCP utility to Enable DHCP.
1. Start the BootP/DHCP Software.
2. Under relation list, add a new entry for the module. Enter the MAC ID of
the module and the known IP address.
3. Select Enable DHCP.
4. A message will appear in the lower left corner indicating that the command
was successful.
IMPORTANT
If you do not select Disable BOOTP/DHCP, then on a power cycle the module
clears the current IP configuration and begins sending DHCP requests again.