Description of Operation
Key to Symbols
Status/Diagnostic Status
Indicators
Status indicator not illuminated
Status indicator illuminated
Status indicator flashes
X
Any state
Operating Mode
LED Indicator
State
1
Power (Green)
State (Green)
Diagnostic (Red) Lock (Yellow)
Diagnostics
On
Green flash 1 x
On
Off
Error during handle configuration or invalid DIP switch setting
Green flash 2 x
Off
Input error (only applies when switch is configured for series operation)
2
Green flash 3 x
Off
Handle assembly read error
Green flash 4 x
Off
Output error
2
Off
Yellow flash 1
Signal
Signal sequence erroneous, escape release or manual release was actuated
2
Off
Off
Internal fault
2
Setup
Off
Off
Off
Handle configuration completed. Cycle power to resume normal operation.
Normal Operation
Flashes green approximately
every three seconds
Off
Off
Normal operation, door is open
1
See the user manual (pub. no. 442G-UM001A-EN-P) for more information on Troubleshooting.
2
Latching faults. All other faults are non-latching. Reset according to the “Clearing Faults” section.
Содержание Allen-Bradley Guardmaster 442G-MAB B-U Series
Страница 12: ...12 Rockwell Automation Publication 440G UM001B EN P May 2016 Chapter 1 General Description Notes ...
Страница 26: ...26 Rockwell Automation Publication 440G UM001B EN P May 2016 Chapter 3 Installation and Wiring Notes ...
Страница 58: ...58 Rockwell Automation Publication 440G UM001B EN P May 2016 Chapter 6 Specifications Notes ...
Страница 66: ...66 Rockwell Automation Publication 442G UM001B EN P May 2016 Appendix A Troubleshooting and Assistance Notes ...
Страница 67: ......