![Rockwell Automation Allen-Bradley 6200P-NS3A1 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/rockwell-automation/allen-bradley-6200p-ns3a1/allen-bradley-6200p-ns3a1_installation-instructions-manual_1475663012.webp)
12
Rockwell Automation Publication 6200-IN001A-EN-P - October 2019
VersaView 5000 Thin Clients, Industrial Computers, and Accessories for Hazardous Locations
Hardware Features
This section shows the hardware features of VersaView 5000 devices for hazardous locations.
Figure 3 - Hardware Features of VersaView 5000 Devices for Hazardous Locations
Connect Power
VersaView 5000 devices for hazardous locations are factory shipped to be connected to a
12…24V DC power source.
Item
Component
Item
Component
1
12…24V DC power input connection
7
Power light-emitting diode (LED)
2
2 x Ethernet LAN port
8
SSD LED
3
USB 3.0 port
9
Power button
4
2 x USB 2.0 port
10
VGA port
5
Serial COM port, RS-232
11
Ground stud
6
DisplayPort
(1)
(1)
Audio output/line out supported.
ATTENTION:
When you connect power to the VersaView 5000 device for hazardous locations for
the first time, these actions occur:
• The default UEFI setting automatically starts the VersaView 5000 device after it is plugged into
a power source.
• For VersaView 5000 devices with a Windows operating system (OS), you must read and accept
an End User Setup procedure.
Do not disconnect power from the system until after the Windows Setup procedure is
completed. If power is disconnected during this procedure, it can result in a corrupted system
image.
1
2
3
4
5
6
10
9
7
8
11