Chapter 7
Parameter Overview
Service Message
Figure 120 - AOP
Figure 121 - WebConnect
Enabled (AOP)/Status (WebConnect)
When Service Message is enabled, a message of up to 10 ASCII characters is sent
whenever the system detects that the limit of the service timer has been reached.
The service timer is reset at power-on, meaning that the limit of the service timer
is the amount of time since last reset. Service timer increments can be set in
seconds or minutes.
Service Message
When enabled, up to a 10-character message is sent whenever the system detects
that the service elapsed time has expired. The service timer is reset on powerup,
therefore the timer is time since last reset. The service timer has a resolution field
for configuring the timer increment; options are seconds our minute increments.
Threshold
The threshold value that the service timer sends the service message.
• Default: Disabled
• Options: 0 = Disabled
1 = Enabled
• Default: SERVICE
• Options: An ASCII string from 1…10 characters
• Default: 300 (5 min)
• Options: 0 = Seconds
1 … 65,535