62
Rockwell Automation Publication 2094-UM001D-EN-P - May 2010
Chapter 4
Kinetix 6000 Connector Data
IAM and AM Motor Power and Brake Connector Pinout
Table 26 - Motor Power Connector
Table 27 - Motor Brake/Resistive Brake Connector
MP Pin
Description
Signal
4
Chassis ground
3
Three-phase motor power
W
2
V
1
U
IMPORTANT
Combined motor-power cable length for all axes on the same DC bus
must not exceed 240 m (787 ft) with 460V systems or 160 m (525 ft) with
230V systems. Drive-to-motor power cables must not exceed 90 m
(295.5 ft).
System performance was tested at these cable length specifications.
These limitations also apply when meeting CE requirements.
BC Pin
Description
Signal
6
Motor brake connections
MBRK-
5
MBRK+
4
Motor brake common
COM
3
+24V brake input power
(from LIM module or customer supplied)
PWR
2
RBM module connections
(from RBM module and safety string)
DBRK-
1
DBRK+
Содержание Allen-Bradley 2094-BC01-M01-S
Страница 4: ...4 Rockwell Automation Publication 2094 UM001D EN P May 2010 Summary of Changes Notes...
Страница 10: ...10 Rockwell Automation Publication 2094 UM001D EN P May 2010 Table of Contents Notes...
Страница 126: ...126 Rockwell Automation Publication 2094 UM001D EN P May 2010 Chapter 5 Connecting the Kinetix 6000 Drive System Notes...
Страница 228: ...228 Rockwell Automation Publication 2094 UM001D EN P May 2010 Appendix B Interconnect Diagrams Notes...
Страница 270: ...270 Rockwell Automation Publication 2094 UM001D EN P May 2010 Appendix F RBM Module Interconnect Diagrams Notes...
Страница 278: ...278 Rockwell Automation Publication 2094 UM001D EN P May 2010 Index Notes...
Страница 279: ......