Rockwell Automation Publication 1606-RM124A-EN-P - September 2021
13
DC/DC Converter - 48V/48V, 5 A, 240 W Reference Manual
Electromagnetic
Compatibility
The electromagnetic compatibility (EMC) behavior of the device is designed
for applications in industrial, residential, commercial, and light industrial
environments.
The device is investigated according to EN 61000-6-1, EN 61000-6-2,
EN 61000-6-3, and EN 61000-6-4.
EMC immunity information is provided in the following table.
EMC emission information is provided in the following table.
Switching frequency information is provided in the following table.
Attributes
Standards
Values
Criteria
(1)
(1) Criterion A: The device shows normal operation behavior within the defined limits.
Criterion C: Temporary loss of function is possible. The device can shut down. If it shuts down, it then restarts by itself.
No damage or hazards for the device occur.
Electrostatic discharge
EN 61000-4-2
Contact discharge
8 kV
Criterion A
Air discharge
15 kV
Criterion A
Electromagnetic RF field
EN 61000-4-3
80 MHz…2.7 GHz
20V/m
Criterion A
Fast transients (Burst)
EN 61000-4-4
Input lines
4 kV
Criterion A
Output lines
2 kV
Criterion A
Surge voltage on input
EN 61000-4-5
+
-
1 kV
Criterion A
+
- chassis ground 2 kV
Criterion A
Surge voltage on output
EN 61000-4-5
+
-
500V
Criterion A
+
- chassis ground 1 kV
Criterion A
Conducted disturbance
EN 61000-4-6
0.15…80 MHz
20V
Criterion A
Attributes
Standards
Notes
Conducted emission on input
lines
IEC/CISPR 16-1-2, IEC/CISPR 16-2-1
Limits for local DC power networks fulfilled.
Conducted emission on
output lines
IEC/CISPR 16-1-2, IEC/CISPR 16-2-1
(1)
(1) Not available at the time of publishing.
Radiated emission
EN 55011, EN 55022, CISPR 11, CISPR 22
Class B
This device complies with FCC Part 15 rules.
Operation is subjected to following two conditions:
1) this device cannot cause harmful interference, and
2) this device must accept any interference received, including interference that can cause undesired operation.
Attribute
Values
Notes
Main converter
75…500 kHz
Dependent on input voltage and output load