Lighting, Site
No special lighting is required for proper operation of the QuickStick HT transport system.
Maintenance can require a user-supplied service lamp (for example, a flashlight).
Floor Space and Loading
The site for the QuickStick HT transport system must meet the minimum space requirements
that are defined after developing the layout as defined in
.
to make sure that there is proper clearance for
installation, operation, and servicing of the QSHT motors and other components. The dimen-
sions that are given are for the QSHT motors and other components only. The user must make
sure that there is adequate space for operation and service around the equipment that is based
on their needs and any vehicle overhang.
Facilities
The user is responsible for providing the facilities that are specified in
to support proper operation of the QuickStick HT motors and other compo-
nents. See
for the connection of all facilities to the QSHT
transport system.
The facility is responsible for the main disconnect device between the QuickStick HT trans-
port system and the power source, making sure it complies with the appropriate facility, local,
and national electrical codes. Service to the QuickStick HT transport system must have the
appropriate circuit breaker rating.
Service Access
The QuickStick HT transport system requires adequate space for service access and for proper
operation. The typical service space that is required for the QSHT motors is shown in
. Typical service space that is required for the QSMC motor
. See the
Node Controller Hardware User
Manual
, for the service space required for the node controllers.
Make sure that installation of the QuickStick HT transport system is such that it provides
access to items required for service after installation, such as power and communication con-
nections.
NOTE:
The Exclusion Zones that are shown are for the QuickStick HT transport system
components only. Additional exclusion zones may be required based on the design
of the vehicle and the material that the QuickStick HT transport system is moving.