Maintenance
Repair
78
MagneMotion
Rockwell Automation Publication MMI-UM037A-EN-P - April 2020
Replace Pucks
Pucks must be replaced if they become damaged or worn. Additionally, pucks can be added
to, or removed from, the transport system if the quantity of pucks in use is not correct. If the
transport system does not contain an open spur that can be used to insert or remove pucks, use
the following procedure to replace either glide or wheeled pucks.
Required Tools and Equipment
•
Torque wrench with the following bits:
•
4 mm Hex.
•
T30 Torx.
•
Loctite 243, Thread locker, Anaerobic Adhesive, Blue.
CAUTION
Strong Magnets
To avoid severe injury, people with pacemakers and other
medical electronic implants must stay away from the magnet
array on the vehicles (pucks).
To avoid injury from strong magnetic attractive forces:
•
Handle only one vehicle (puck) or magnet array at a time.
•
Do not place any body parts, such as fingers, between a
vehicle (puck) or magnet array and any ferrous material
or another magnet array.
•
Vehicles (pucks) or magnet arrays not being used must be
secured individually in isolated packaging.
To avoid damage to watches, instruments, electronics, and
magnetic media, keep metal tools, metal objects, magnetic
media (for example, memory disks/chips, credit cards, and
tapes) and electronics away from the magnet arrays.