Rockwell Automation Publication 440G-UM003A-EN-P - February 2020
21
Installation
Chapter 4
• For flush mount: mount the sensor in the fixed part of the protective
device.
3.
Set cover plate on the sensor.
4.
Tighten the fixing screws to 1 N•m.
Mount the Actuator
1.
Align the actuator to the mounted sensor.
2.
Mount the actuator on the moving part of the protective device (for
example, door) with 4 x M4 screws. Tightening torque: 1 N•m. Use
disposable screws if possible.
• Maximum angle between sensor and actuator when protective device is
closed is 3°
3.
Cover drill holes of the actuator with protective caps.
Tightening torque: 1 N•m
≤ 3°