Rockwell Automation Publication 1783-UM014A-EN-P - October 2021
35
Chapter 2 Router Integration
Update the System
The software components upgrades are distributed in the format of one file
that works as “container” for the components to be replaced.
To execute an update, copy the file on the root folder of the USB Stick. Insert
the USB stick into the routers USB port and cycle the power. During the
power-up phase, the router recognizes the USB stick with the update and it
starts the system software update procedure.
No further action is needed. The update is completed after the router
automatically restarts.
Factory Reset
The factory settings for the Ethernet interfaces are shown in the following
table.
The access to the Router configuration is protected with a combination user/
password.
The default username and password are both “admin.”
The factory settings information is printed on the Router side with the MAC
addresses of the two network interfaces. The MAC addresses assigned to the
two network interfaces are also printed.
To complete a factory reset, use the following steps.
1. Turn off the device.
2. Press and hold the factory reset button and turn on the device.
3. When the Server/USB status indicator is alternating blinking red and
green for at least 15 seconds, release the button.
Following these steps, the router performs the deletion of the system and a
complete reset. Do not to turn off or remove the power supply to the router in
this phase.
During the factory reset, the Server/USB indicator blinks green. This blink
signals that the process is working. Wait until the process is automatically
completed. If the router shuts down during this process, the factory reset is not
completed.
At the end of the reset process, the Server/USB indicator turns on and starts to
blink. When the indicator is blinking red, the reset is complete.
You can also update by clicking the update link in the cloud portal page.
Interface
IP Address
Mask
LAN
192.168.0.1
255.255.255.0
WAN
DHCP
This protection is independent from the security handling that is related to the
Domain users. The user/password account is a local device protection.
Содержание 1783-RA2TGB
Страница 6: ...6 Rockwell Automation Publication 1783 UM014A EN P October 2021 Notes...
Страница 20: ...20 Rockwell Automation Publication 1783 UM014A EN P October 2021 Chapter 1 Remote Access Architecture Notes...
Страница 40: ...40 Rockwell Automation Publication 1783 UM014A EN P October 2021 Notes...
Страница 41: ...Rockwell Automation Publication 1783 UM014A EN P October 2021 41 Stratix 4300 Remote Access Routers User Manual...