Appendix C Troubleshoot Your System
When a fault condition is detected, the analog outputs are reset to zero.
Power-up Diagnostics
At module power-up, a series of internal diagnostic tests are performed.
Critical and Non-Critical Errors
Non-critical module errors are recoverable. Channel errors (over-range or
under-range errors) are non-critical. Non-critical error conditions are
indicated in the module input data table. Non-critical configuration errors are
indicated by the extended error code. See
Critical module errors are conditions that prevent normal or recoverable
operation of the system. When these types of errors occur, the system leaves
the run mode of operation. Critical module errors are indicated in
.
Module Error Definition Table
Analog module errors are expressed in two fields as four-digit Hex format with
the most significant digit as “don’t care” and irrelevant. The two fields are
“Module Error” and “Extended Error Information”. The structure of the
module error data is shown below.
Module Error Field
The purpose of the module error field is to classify module errors into three
distinct groups, as described in the table below. The type of error determines
what kind of information exists in the extended error information field. These
types of module errors are typically reported in the controller’s I/O status file.
See MicroLogix 1400 Programmable Controllers Instruction Set Reference
Manual, publication
for more information.
.
Module Status LED State Table
If module status LED is
Indicated condition
Corrective action
On
Proper Operation
No action required.
Off
Module Fault
Cycle power. If condition persists, replace the module. Call
your local distributor or Allen-Bradley for assistance.
Module Error Table
“Don’t Care” Bits
Module Error
Extended Error Information
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Hex Digit 4
Hex Digit 3
Hex Digit 2
Hex Digit 1
Module Error Types
Error Type
Module Error Field Value
Bits 11 through 09 (Binary)
Description
No Errors
000
No error is present. The extended error field holds no additional information.
Hardware Errors
001
General and specific hardware error codes are specified in the extended error information field.
Configuration Errors
010
Module-specific error codes are indicated in the extended error field. These error codes correspond to
options that you can change directly. For example, the input range or input filter selection.
Содержание 1766-L32AWA
Страница 10: ...10 Rockwell Automation Publication 1766 UM001O EN P September 2021 Table of Contents Notes ...
Страница 18: ...18 Rockwell Automation Publication 1766 UM001O EN P September 2021 Chapter 1 Hardware Overview Notes ...
Страница 56: ...56 Rockwell Automation Publication 1766 UM001O EN P September 2021 Chapter 3 Wire Your Controller Notes ...
Страница 122: ...122 Rockwell Automation Publication 1766 UM001O EN P September 2021 Chapter 5 LCD and Keypad Notes ...
Страница 152: ...152 Rockwell Automation Publication 1766 UM001O EN P September 2021 Appendix B Replacement Parts Notes ...
Страница 160: ...160 Rockwell Automation Publication 1766 UM001O EN P September 2021 Appendix C Troubleshoot Your System Notes ...
Страница 302: ...302 Rockwell Automation Publication 1766 UM001O EN P September 2021 Glossary Notes ...
Страница 308: ...308 Rockwell Automation Publication 1766 UM001O EN P September 2021 Index Notes ...