GuardLogix 5580 Controllers Installation Instructions

Parts List

The controller ships with these parts:

A key for the mode switch

2 GB Secure Digital Card (1784-SD2), pre-installed in the controller 

IEC Hazardous Location Approval

The following applies to products with IECEx certification: 

• Are intended for use in areas in which explosive atmospheres caused by gases, vapors, mists, or air are unlikely to occur, or are likely to occur only infrequently and 

for short periods. Such locations correspond to Zone 2 classification to IEC 60079-0.

• The type of protection is Ex nA IIC T4 Gc according to IEC 60079-15.

• Such modules comply to Standards IEC 60079-0:2011, IEC 60079-15:2010, reference IECEx certificate number IECExUL14.0008X.

• May have catalog numbers followed by a "K" to indicate a conformal coating option.

Special Conditions for Safe Use

WARNING: 

• This equipment is not resistant to sunlight or other sources of UV radiation.
• This equipment shall be mounted in an ATEX/IECEx Zone 2 certified enclosure with a minimum ingress protection rating of at least IP54 

(as defined in EN/IEC 60079-15) and used in an environment of not more than Pollution Degree 2 (as defined in EN/IEC 60664-1) when 

applied in Zone 2 environments. The enclosure must be accessible only by the use of a tool.

• This equipment shall be used within its specified ratings defined by Rockwell Automation.
• Provision shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 140% of the rated 

voltage when applied in Zone 2 environments.

• The instructions in the user manual shall be observed.
• This equipment must be used only with ATEX/IECEx certified Rockwell Automation backplanes.
• Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous.
• The USB port is intended for temporary local programming purposes only and not intended for permanent connection. Do not use the 

USB port in hazardous locations.

Environment and Enclosure

ATTENTION: 

This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as 

defined in EN 60664-1), at altitudes up to 2000 m (6562 ft) without derating. 

This equipment is not intended for use in residential environments and may not provide adequate protection to radio communication 

services in such environments.

This equipment is supplied as open-type equipment for indoor use. It must be mounted within an enclosure that is suitably designed for 

those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from 

accessibility to live parts. The enclosure must have suitable flame-retardant properties to prevent or minimize the spread of flame, 

complying with a flame spread rating of 5VA or be approved for the application if non-metallic. The interior of the enclosure must be 

accessible only by the use of a tool. Subsequent sections of this publication may contain more information regarding specific enclosure 

type ratings that are required to comply with certain product safety certifications.

In addition to this publication, see the following:
• Industrial Automation Wiring and Grounding Guidelines, publicatio

1770-4.1

, for more installation requirements

• NEMA Standard 250 and EN/IEC 60529, as applicable, for explanations of the degrees of protection provided by different types of 

enclosure.

Programmable Electronic Systems (PES)

ATTENTION: 

Personnel responsible for the application of safety-related Programmable Electronic Systems (PES) shall be aware of the safety 

requirements in the application of the system and shall be trained in using the system.

IMPORTANT

Any illustrations, charts, sample programs, and layout examples shown in this publication are intended solely for the purposes of example. Since 

there are many variables and requirements associated with any particular installation, Rockwell Automation does not assume responsibility or 

liability for actual use based upon the examples shown in this publication.

Содержание 1756-L81ES

Страница 1: ...de up of a primary controller and a safety partner for SIL 3 applications that function together in a 1oo2 architecture With a safety partner installed GuardLogix controllers are Type approved and certified for use in safety applications up to and including SIL 3 per IEC 61508 EC Type approved for use in safety applications up to and including SIL CL3 per IEC 62061 EC Type approved for use in safe...

Страница 2: ...nnes formées selon le code de pratique en vigueur Si cet équipement est utilisé d une façon qui n a pas été définie par le fabricant la protection fournie par l équipement peut être compromise ATTENZIONE Prima di installare configurare ed utilizzare il prodotto o effettuare interventi di manutenzione su di esso leggere il presente documento ed i documenti elencati nella sezione Altre risorse rigua...

Страница 3: ...le code de température pour les environnements dangereux Lorsque plusieurs produits sont combinés dans un système le code de température le plus défavorable code de température le plus faible peut être utilisé pour déterminer le code de température global du système Les combinaisons d équipements dans le système sont sujettes à inspection par les autorités locales qualifiées au moment de l install...

Страница 4: ...permanent connection Do not use the USB port in hazardous locations Environment and Enclosure ATTENTION This equipment is intended for use in a Pollution Degree 2 industrial environment in overvoltage Category II applications as defined in EN 60664 1 at altitudes up to 2000 m 6562 ft without derating This equipment is not intended for use in residential environments and may not provide adequate pr...

Страница 5: ...C and series B 1756 A4 1756 A4K 1756 A7 1756 A7K 1756 A10 1756 A10K 1756 A13 1756 A13K 1756 A17 1756 A17 K Power supply standard 1756 PA72 1756 PA72K 1756 PA75 1756 PA75K 1756 PB72 1756 PB72K 1756 PB75 1756 PB75K 1756 PH75 1756 PC75 Power supply redundant 1756 PA75R 1756 PA75RK 1756 PB75R 1756 PB75RK 1756 PSCA2 1756 PSCA2K 139 6 mm 5 50 in 34 55 mm 1 360 in 145 2 mm 5 717 in Front view GuardLogix ...

Страница 6: ...ion you can use a Series B chassis derating to 50 C 122 F or Series C chassis with no restrictions WARNING When you insert or remove the module while backplane power is on an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding Repeated electrical arcing causes excessive wear to contac...

Страница 7: ...therNet IP network then connect an RJ45 cable to the Ethernet port on the controller Confirm Installation After you insert the controller into the chassis and apply power the 4 character display and status indicators provide information about the controller See the ControlLogix 5580 and GuardLogix 5580 Controllers User Manual publication 1756 UM543 for information on how to interpret the 4 charact...

Страница 8: ... Ta 60 C 32 F Ta 140 F for Series C Chassis Note If operating above 55 C 131 F modules greater than 6 2W shall not be installed in slots adjacent to the controller Temperature operating SIL 3 PLe IEC 60068 2 1 Test Ad Operating Cold IEC 60068 2 2 Test Bd Operating Dry Heat IEC 60068 2 14 Test Nb Operating Thermal Shock 0 C Ta 60 C 32 F Ta 140 F for Series C Chassis 0 C Ta 50 C 32 F Ta 122 F for Se...

Страница 9: ...ollers User Manual publication 1756 UM543 Provides information on how to configure select I O modules manage communication develop applications and troubleshoot the ControlLogix 5580 controllers GuardLogix 5580 and Compact GuardLogix 5380 Controller Systems Safety Reference Manual publication 1756 RM012 Provides information on safety application requirements for GuardLogix 5580 and Compact GuardLo...

Страница 10: ...10 Rockwell Automation Publication 1756 IN048D EN P March 2021 GuardLogix 5580 Controllers Installation Instructions Notes ...

Страница 11: ...Rockwell Automation Publication 1756 IN048D EN P March 2021 11 GuardLogix 5580 Controllers Installation Instructions Notes ...

Страница 12: ...lectrical and Electronic Equipment WEEE Rockwell Automation maintains current product environmental compliance information on its website at rok auto pec At the end of life this equipment should be collected separately from any unsorted municipal waste Rockwell Automation Support Use these resources to access support information Documentation Feedback Your comments help us serve your documentation...

Отзывы: